Chapter 2: Hardware Overview
StorNext M660 Connectivity
40
StorNext M660 Metadata Appliance Hardware Guide
Table 8 StorNext M661
Network Configuration
The default StorNext M662 network interface configuration is as
follows:
• Two interfaces, Eth2 and Eth3, bonded together into bond0 for the
Metadata network. This bond can be broken in the GUI and the
service menu. When not bonded, Eth2 will be configured as a
standalone port and Eth3 will be de-configured and not used by the
system.
• Two interfaces, Eth1 and Eth4, are bonded together into bond1 for
GUI/management. This bond can be broken in the GUI and the
service menu. When not bonded, Eth1 will be configured as a
standalone port and Eth4 will be de-configured and not used by the
system.
• The remaining five ports can be configured through the GUI in
various combinations and bonds for gateway port access.
Ethernet
Port
Number
Logical
Ethernet
Port Number
Physical Port
Location
Port Function
Bond
D
N/A
iDRAC Port
Service
N/A
S
eth0
Integrated Port 1
1
eth1
Integrated Port 2
GUI and Management
(Configurable from Service Menu)
Bond 1
When not bonded, eth1 is usable
and eth4 is not usable
2
eth2
Integrated Port 3
Metadata
(Configurable from
Service Menu)
When not bonded, eth2 is usable
and eth3 is not usable
3
eth3
Integrated Port 4
Bond 0
When not bonded, eth3 is not used
4
eth4
Slot 2, Port 1
GUI and Management
(Configurable from Service Menu)
Bond 1
When not bonded, eth4 is not used
5
eth5
Slot 2, Port 2
Gateway
User Configurable from GUI
6
eth6
Slot 2, Port 3
7
eth7
Slot 2, Port 4
8
eth8
Slot 1, Port 1
9
eth9
Slot 1, Port 2
10
eth10
Slot 1, Port 3
11
eth11
Slot 1, Port 4