4-33
Procedure:
1. Select the
LAN Interface
from the drop down list.
2. Check
Enable
to enable the LAN Settings.
3. In IPv4 Configuration, enable
Use DHCP to Obtain an IP
address automatically
to dynamically configure IPv4
address using DHCP.
4. If the field is disabled, enter the
IPv4 Address
,
Subnet
Mask
and
Default Gateway
in the respective fields.
5. In IPv6 Configuration, if you wish to enable the IPv6 set-
tings, check
Enable
.
6. If the IPv6 setting is enabled, enable or disable the option
Use DHCP for obtaining the IP address automatically
.
7. If the field is disabled, enter the
IPv6 Address, Subnet
Prefix length
and
Default Gateway
in the given field.
8. In VLAN Configuration, if you wish to enable the VLAN
settings, check
Enable
.
9. Enter the
VLAN ID
in the specified field.
10.Enter the
VLAN Priority
in the specified field.
11.Click
Save
to save the entries.
12.Click
Reset
if you want to reset the modified changes.
PEF
Platform Event Filtering (PEF) provides a mechanism for con-
figuring the BMC to take selected actions on event messages
that it receives or has internally generated. These actions
include operations such as system power-off, system reset, as
well as triggering the generation of an alert. In MegaRAC GUI,
the PEF Management is used to configure the following fea-
tures:
Event Filter
Alert Policy
LAN Destination
To open PEF Management Settings page, click
Configurations
> PEF
from the main menu. A sample screenshot of PEF Man-
agement Settings Page is shown in the screen shot below
along with an explanation of each of the tabs.
Event Filter Tab
A PEF implementation is recommended to provide at least 16
entries in the event filter table. A subset of these entries should
be pre-configured for common system failure events, such as
over-temperature, power system failure, fan failure events, etc.
Remaining entries can be made available for ‘OEM’ or System
Management Software configured events. Note that individual
entries can be tagged as being reserved for system use - so
Reset
To Reset the modified changes.
Table 4-23: Network Settings Page (Continued)
I
TEM
D
ESCRIPTION
Summary of Contents for STRATOS S210 Series S210-X12RS
Page 21: ...REVISION HISTORY XXI ...
Page 22: ...About the Server Chapter 1 About the Server Chapter 1 ...
Page 38: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 104: ...BIOS Chapter 3 BIOS Chapter 3 ...
Page 173: ...BMC Chapter 4 BMC Chapter 4 ...
Page 240: ...Jumpers and Connectors Chapter 5 ...
Page 245: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 249: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 259: ...Safety Information Chapter 9 Safety Information Chapter 9 ...