BMC
F
RONT
P
ANEL
U
SER
I
NTERFACE
4-2
turn the LED on (blinking). If the LED is on, a button press or
IPMI Chassis Identify command will turn the LED off.
LEDs
The following table contains information on Status, ID and
Heartbeat LED's.
The following table contains information on Status LED when
amber blinking.
Table 4-1: Status LED, ID LED, and Heartbeat LED
LED
S
C
OLOR
S
TATUS
D
ESCRIPTION
Power /
Status LED
Amber (Status
LED)
Blinking
System Event
(See following
Status LED table.)
Off
Normal status
Green
(Power LED
controlled by BIOS)
On
Power On
Off
Power Off
ID LED
Blue
Off
Normal status
Blinking
Identify the system
with interval
Solid ON
Identify the system
Heartbeat
LED
Green
Off
BMC is not Ready
Blinking
BMC is Ready
Table 4-2: Status LED Activity
N
O
.
S
TATUS
LED
A
CTIVITY
D
ESCRIPTION
1.
Temperature Sensor
Non-critical / critical event asserted
2
Fan Sensors
Non-critical / critical event asserted
3
Voltage Sensors
State asserted
4
Power Supply
State asserted
5.
Processor
Thermal trip
6
Event Logging Disable
SEL almost full
SEL full
7
Post Error
System firmware error
8
Memory
Correctable EEC error
Uncorrectable ECC error
Correctable ECC error logging
limit reached
9.
PCIe Bus
Bus correctable error
Bus uncorrectable error
Bus fatal error
10
BMC Watchdog
Timer expired
Hard Reset
Power Down
Power cycle
Summary of Contents for STRATOS S210 Series S210-X12RS
Page 21: ...REVISION HISTORY XXI ...
Page 22: ...About the Server Chapter 1 About the Server Chapter 1 ...
Page 38: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 104: ...BIOS Chapter 3 BIOS Chapter 3 ...
Page 173: ...BMC Chapter 4 BMC Chapter 4 ...
Page 240: ...Jumpers and Connectors Chapter 5 ...
Page 245: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 249: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 259: ...Safety Information Chapter 9 Safety Information Chapter 9 ...