C
HAPTER
T
ITLE
QUANTA SMASH
4-11
BMC Information
The BMC level commands provide several options to configure
and display parameters of the management agent.
Displays information for the board
show /SP
Reset BMC
reset /SP
Set server identify LED to be off
set /SP ServerIdentify=off
Set server identify LED to be on
set /SP ServerIdentify=on
Set server identify LED to be blinking
set /SP ServerIdentify=blinking
/SP
Table 4-9: Targets and Verbs
R
ELATED
T
ARGETS
S
UPPORTED
V
ERBS
cd
exit
help
create
delete
set
show
reset
start
stop
version
/
v
v
v
v
v
/SP
v
v
v
v
v
v
v
Table 4-10: /SYS/fan
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
BMCVersion
R
Display BMC firmware
revision
BMCGUID
R
Display BMC GUID
ServerIdentify
off
on
blinking
R/W
Configuring server
identify LED
BMCMAC
R
Display the NIC physical
address used by server
management agent
Summary of Contents for STRATOS S210 Series S210-X12RS
Page 21: ...REVISION HISTORY XXI ...
Page 22: ...About the Server Chapter 1 About the Server Chapter 1 ...
Page 38: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 104: ...BIOS Chapter 3 BIOS Chapter 3 ...
Page 173: ...BMC Chapter 4 BMC Chapter 4 ...
Page 240: ...Jumpers and Connectors Chapter 5 ...
Page 245: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 249: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 259: ...Safety Information Chapter 9 Safety Information Chapter 9 ...