5.2.5.2 show gvrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or all
interfaces.
Syntax
show gvrp configuration [{<slot/port> | port-channel <portchannel-id>}]
<slot/port> - Specifies the desired interface.
<portchannel-id> - Specifies the port-channel interface. The range of port-channel ID is 1 to 64.
no parameter - All interfaces.
Default Setting
None
Command Mode
Privileged Exec
User Exec
Display Message
Interface: This displays the slot/port of the interface that this row in the table describes.
Join Timer: Specifies the interval between the transmission of GARP PDUs registering (or
re-registering) membership for an attribute. Current attributes are a VLAN or multicast group. There
is an instance of this timer on a per-Port, per-GARP participant basis. Permissible values are 10 to
100 centiseconds (0.1 to 1.0 seconds). The factory default is 20 centiseconds (0.2 seconds). The
finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer: Specifies the period of time to wait after receiving an unregister request for an
attribute before deleting the attribute. Current attributes are a VLAN or multicast group. This may be
considered a buffer time for another station to assert registration for the same attribute in order to
maintain uninterrupted service. There is an instance of this timer on a per-Port, per-GARP participant
basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0 seconds). The factory default is 60
centiseconds (0.6 seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
LeaveAll Timer: This Leave All Time controls how frequently LeaveAll PDUs are generated. A
LeaveAll PDU indicates that all registrations will shortly be deregistered. Participants will need to
rejoin in order to maintain registration. There is an instance of this timer on a per-Port, per-GARP
participant basis. The Leave All Period Timer is set to a random value in the range of LeaveAll- Time
to 1.5*LeaveAllTime. Permissible values are 200 to 6000 centiseconds (2 to 60 seconds). The
factory default is 1000 centiseconds (10 seconds). The finest granularity of specification is 1
centisecond (0.01 seconds).
Port GVRP Mode: Indicates the GVRP administrative mode for the port. It may be enabled or
disabled. If this parameter is disabled, Join Time, Leave Time, and Leave All Time have no effect.
The factory default is disabled.
Summary of Contents for QuantaMesh
Page 17: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Introduction 17 ...
Page 224: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 224 ...
Page 226: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 226 ...
Page 229: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 229 ...
Page 411: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 411 ...
Page 514: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 514 Global Config ...
Page 631: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 631 ...
Page 636: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 636 ...
Page 644: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh Switching Commands 644 Global Config ...
Page 862: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh IP Multicast Commands 862 ...
Page 912: ...UANTA COMPUTER INC Layer 2 3 4 Managed Switch QuantaMesh IPv6 Commands 912 8 3 1 8 ...