8 0
Q U A L I T Y F R Y
M
ai
nt
enan
ce
Use personal protection equipment (anti-cut gloves for work with
steel or sheet metal and protective gloves or utensils against
chemical agents) as mentioned in the Safety section.
Biannual or Annual
1 . C L E A N I N G T H E D E C A N T E R H E A T I N G C O I L
- It is recommended to perform this maintenance when it coincides
with bimonthly maintenance, as the “gas extraction elbow” must be
removed first. Then remove the 1” fitting into which the extraction
elbow is inserted.
- Remove the left side cover behind the machine fastened with
screws to cover the coil.
- Then disconnect the coil connection to the condensation drum.
After removing this connection, remove the retaining nut from the
coil.
- Once all the connections to the coil have been disconnected, lift
the protective cover and remove the coil from inside the machine for
cleaning.