5. Screw the drain tube into the lower part of the coil with a 1 ”fitting.
6. Place fill tube (22 x 4 mm) on top of coil.
7. Introduce the two tubes through the product inlet, for this it must
be without the hatch or the carousel in the upper part. Try not to
form creases in the tubes.
8. Pour hot water with degreaser through the tube that connects to
the top of the coil with a funnel.
9. Let the product act for 15 to 20 minutes.
10. Carefully remove the tube that connects to the lower part of the
coil (housed in the product inlet).
11. Pour the dirty water into a bucket.
12. Rinse with hot water, introducing it with the funnel through the
upper tube.
13. Repeat this process until clean water is extracted.
5 7