May 23, 2013
7075-166C
Page 39
VOYAGEUR GRAND Wood Insert
R
A. Outside Air Kit Installation
Items Needed for Installation (not supplied)
• 4 inch flex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible, heat
resistant material up to 350
o
F. Cut the pipe to the required
length for your installation.
• Phillips head screw driver
• Silicone sealant
Figure 39.1
A source of air (oxygen) is necessary in order for combustion to
take place. Whatever combustion air is consumed by the fire
must be replaced. Air is replaced via air leakage around win
-
dows and under doors. In homes that have tightly sealed doors
and windows, an outside air source is needed. An optional Out
-
side Air Kit is avail
able.
9
Appliance Set-up
WARNING
Do not draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or
chimneys
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust flue.
•
Fire will not burn properly
•
Smoke spillage occurs when door is opened due
to air starvation.
WARNING
Option One - Outside Air Installation Instructions
1. Swing grille down to expose the two screws.
Figure
39.1
2. Remove the two screws and pull the access assembly
away from the appliance.
3. Assemble the outside air cover plate A supplied in com
-
ponent pack.
4. Re-install the access assembly.
5. Remove the outside air cover plate B on outer can and dis-
card.
Figure 39.2.
6. Install optional flex adapter to outer can with the same
screws. Do not use plastic wire ties that come with the kit as
they will melt. NOTE: You may need to install the flex pipe
into the firebox first depending on installation. Attach flex to
adapater with at least 2 screws.
7. Ensure existing access hole in fireplace is sufficient to feed
the 4 inch flex.
8. After sliding can into fireplace, feed flex into cut opening to
obtain outside combustion air.
9. Level outer can and install appliance. See
page 40.
Option Two - Outside Air Installation Instructions
1. Follow steps 1-5 in Option One above
2. Ensure existing acces hole in fireplace will not be covered by
the outer can. Existing outside air intake hole may be under
at the rear or side of outer can. Outside air may also enter
down existing chimney chase in some situations.
3. Repeat step 9 under Option One with one exception. After
installing the appliance in the outer can, seal the fireplace
opening and trim package with insulation to prevent air leak-
age into the room.
Outside air inlet must be located to prevent blockage from:
• Leaves, snow, ice or other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive indi-
viduals.
WARNING
Asphyxiation Risk.
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Remove Outside Cover
Plate A
(Discard)
Outside Air Cover
Plate B
(Discard)
Termination
Cap
Flex Adapter
Figure 39.2
Remove the zip tie to the lower
access cover. It is to prevent the
cover opening during shipping.