background image

Required Tools

•  Safety Glasses
•  Protective Work Gloves
•  Carpenter’s Level
•  Phillips Screwdriver

General Information

This document details installation instructions for the SV4.5HTKCT, SV4.5HTKCT20, all SFKITXXCT, and 

SF4.5HTKCT horizontal compact termination kits. Information provided here supplements the instructions provided 

with each fireplace and may be redundant to that information. The intent of this document is to provide complete 

instructions for the aforementioned terminations, particularly any instructions exclusive to the installation of 

these terminations.
These horizontal compact terminations are intended for use ONLY with the following IHP direct-vent gas fireplaces: 
•  Aries 33”, -35”, -40”
•  DRT/DRC2033, -2035, and -2040
•  VeniceLightsTEN, VeniceLightsTEP
•  DRL4543TEN, DRL4543TEP

These terminations may not be used with other models. The terminations covered by this document seamlessly 

integrate with all other components of the approved fireplaces, and when installed in accordance with the directions 

provided here—and with the fireplace—constitute a complete, approved and listed installation.

Horizontal Compact 

Termination Kits

P/N 900080-00 
REV. B, 04/2018

HEARTH PRODUCTS

KITS AND ACCESSORIES

INSTALLATION INSTRUCTIONS FOR IHP HORIZONTAL COMPACT 

TERMINATION KITS FOR USE WITH DIRECT-VENT GAS FIREPLACES

[Kit models SV4.5HTKCT, SV4.5HTKCT20, all SFKITXXCT, SF4.5HTKCT]

 WARNING 

HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO 

TOUCH GLASS.
• Install only when fireplace is OFF and COLD.
• Fireplace surfaces get EXTREMELY HOT!
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe 

burns if touched. Even after the gas is turned off, fireplace surfaces remain extremely hot.

• Keep children away from an operating fireplace. Closely supervise children in any room where a 

fireplace is operating to prevent contact with glass.

C

US

Report No. F13-94

Summary of Contents for SV4.5HTKCT

Page 1: ...ed by this document seamlessly integrate with all other components of the approved fireplaces and when installed in accordance with the directions provided here and with the fireplace constitute a complete approved and listed installation Horizontal Compact Termination Kits P N 900080 00 REV B 04 2018 HEARTH PRODUCTS KITS AND ACCESSORIES INSTALLATION INSTRUCTIONS FOR IHP HORIZONTAL COMPACT TERMINA...

Page 2: ...f the termination onto the adaptor the outer over the outer and the inner inside the inner until the termination seats against the exterior wall surface to which it will be attached NOTE Orient the housing of the termination with the arrow pointed upwards 2 Secure the termination to the exterior wall NOTE The horizontal termination must not be recessed into the exterior wall or siding by more than...

Page 3: ...o the base of the fireplace NOTE To help minimize water infiltration install the firestop spacer SV4 5HF on the exterior side of the wall Figure 2 Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination SV4 5HTKCT Siding Stucco 1 1 4 Maximum Recess of the Square Termination into Exterior Finishing Material Exterior Surface of Framing 6 to 9 1 4 152 to 235 mm Exterior S...

Page 4: ...llowed if 45 elbows are used NOTE Maintain the horizontal inclined run in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 per 1 ft 20 mm per 1 m horizontal in a direction away from the fireplace Smaller rise per foot run ratios are acceptable all the way to at or near level Use a carpenter s level to measure from a constant surface and adjust the support str...