May 23, 2013
7075-166C
Page 45
VOYAGEUR GRAND Wood Insert
R
8. The power cord is now disconnected from the blower
control plate. Pull the cord out through the right side
of the appliance.
Route Cord Through
Retainer Clip
Grommet
9. Insert the power cord throught the left side of the
appliance in the hole contains the grommet. Pull the
connection ends to the right side. Route the power
cord through the retainer clip.
Strain Relief
10. Replace the strain relief on the power cord in the
same position as before. Locate the indentation on
the cord made by the strain relief. Once replaced,
push the strain relief back into the control plate.
White Wire
Black Wire
Fiber
Wrapped
Wire
Green
Grounding
Wire
11. Connect the white wire on the power cord into the
fiber wrapped wire on the wire harness. Connect the
black wire on the power cord to the white wire on the
rheostat. Re-attach the green ground terminal to the
control plate.
12. Insert the control plate assembly back into the
appliance as shown. Tilt the assembly forward and
then lift up and rotate the bottom towards the front
of the appliance at the same time ensure that the
snap disc holder is properly seated. Secure plate
to the appliance.
Figure 45.1
Figure 45.2
Figure 45.3
Figure 45.4
Figure 45.5
Route Wires through Retainer Clip
Replace Screws in Hold Down Bracket
13. Push in the blower and hold down bracket into
appliance matching up the tab on the bracket and
placement slot on the appliance. Secure bracket
and reconnect blower wires (no polarity to worry
about) routing wires through the retainer clip.
Figure 45.6