VOYAGEUR GRAND Wood Insert
R
5
Service Parts Replacement
A. Glass Replacement
(Replace with 5mm ceramic glass only)
1.
Ensure that the fire is out and the appliance is cool to
the touch.
2. Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3. Remove the door with the broken glass by lifting the
door up and off of the hinges.
4. Lay door face down on a table or counter making sure
the handle hangs over the edge so the door lays flat, on
a soft surface.
5. Remove the screws from each glass retainer and remove
the glass. (If screws are difficult to remove, soak with
penetrating oil first).
6. Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
7. Replace the glass retainers. Be careful not to cross
thread the screws.
8.
Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9. Replace the door on the appliance.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact or
misuse.
WARNING! Risk of Fire or Injury!
Use only glass that is specified in the manual, DO NOT
replace with any other material. Glass breakage will occur.
CAUTION!
Handle glass with care.
• Inspect the gasket to ensure it is undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass & door assembly
removed.
• Do NOT operate with glass cracked, broken or
scratched.
B. Snap Disc Replacement (Cont;d)
Figure 21.1 Snap Disc Location
1. The grille on the blower access assembly is hinged. Swing
the grille downward to expose the 2 screws.
Figure 23.1
on page 23.
Blower Controls & Snap
Disc Under Ash Lip
Snap Disc
UNPLUG APPLICE FROM ANY POWER SOURCE
BEFORE REPLACING ANY COMPONENTS
White
Black
White
Black
Black
White
Blower
Snap Disc
Rheostat
Switch
Power Cord
B. Snap Disc Replacement
2. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance
3
. Locate the snap disc bracket assembly behind the blower
controls on the right side under the ash lip.
Figure 22.1
4. Remove the 2 mounting screws in the blower control
bracket and slide assembly towards you.
5. Using a Phillips head screw driver, remove the 2 screws
from the snap disc and lift the snap disc off of the mounting
bracket. Disconect the wires and replace with new snap
disc and re-connect the wires.
6. Slide the blower control bracket back into position and
secure with the 2 mounting screws.
C. Wiring Diagram
Figure 21.2