May 23, 2013
7075-166C
Page 35
VOYAGEUR GRAND Wood Insert
R
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Follow Manufacturer’s Instructions
on Insulation and Support
For Zero or Other Non-Code Clearances,
Follow Approved Liner Manufacturer’s Specific
Insulation Requirements: Different Clearances
May Require Different Specifications
Masonry Chimney Must
Have Structural Integrity
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry
Thickness in Front of Smoke Chamber
Damper Plate Removed or
Fastened in Open Position
Seal with Non-Combustible Material
Minimum Clearance in Accordance
with Insert Listing
Floor Protection in
Accordance with Insert
Listing
Follow Manufacturer’s
Instructions for Maximum
Liner Extension Above
Chimney
Maximum 30
Degrees
Offset in Chimney
Combustible Floor
Masonry Chimney (Cont’d)
Figure 35.1 - Masonry Chimney with a Full Liner Kit Type UL103HT Rquirement per UL1777
NOTE:
In Canada, this fireplace insert must be installed
with a continuous chimney liner of a 6 inch (152mm) diam
-
eter extending from the fireplace insert to the the top of the
chimney.
The chimney liner must conform to the Class 3 require-
ments of CAN/ULC-S635, Standard for Lining Systems for
Existing Masonry or Factory-Built Chimneys and Vents,
or CAN/ULC-S640, Standard for Lining Systems for New
Masonry Chimneys.
This insert conforms with the UL 1482 and ULC S628
(Canada) in all respects, and is approved to UL & ULC
safety standards for installation and use within a fireplace
with a masonry chimney in accordance with NFPA 211 and
CAN/CSA-B365-01.
NOTE: Generic wood insert shown - not model specific
In USA a minimum 5 foot length, 6 inch diameter flue
liner is required as per UL 1482, however Hearth &
Home Technologies
strongly
recommends a full reline
for optimum performance.