GARNET DIRECT VENT ROOM HEATER
250-6443B October 7, 2003 Page 7
R
GARNET DIRECT VENT ROOM HEATER
250-6443B October 7, 2003 Page 8
R
LP CONVERSION INSTRUCTIONS
KIT CONTENTS: Replacement orifice; replacement
pilot injector; valve regulator; conversion label.
TOOLS REQUIRED: Power drill (a 90° handle is
helpful) or slotted screwdriver or Torx TH20; #2
Phillips bit; 5/32" Allen wrench; 5/8" open end
wrench
.
1. Remove front (if installed), glass, and logs (if
installed).
2. Remove log/burner pan: First remove screws then lift
side of pan vertically and pull out of firebox.
(Fig. 1)
3. Remove burner: Loosen shutter set screw and slide
shutter all the way to the right (closed). Lift left side of
burner and slide to the left.
4. Pull off pilot hood and set aside. (
Fig. 2)
5. Use a 5/32" Allen wrench to remove the pilot injector.
(
Fig. 3)
6. Replace pilot injector with the appropriate size injector
supplied with the stove (#35 for Propane, #62 for Natural
Gas).
7. Replace pilot hood, snapping into position.
8. Remove main burner orifice using a 5/8" wrench. (
Fig. 4)
9. Replace orifice with the proper size as indicated below
for your gas type and venting.
PROPANE
NATURAL GAS
.0469
.078
10. Reinstall burner. Slide burner neck into shutter and
over orifice. Install log/burner pan using the three
screws removed.
See page 9 for Valve Regulator Replacement
.
FIG. 1
FIG. 2
FIG. 3
FIG. 4
5/32" Allen Wrench
NOTE: Have the gas supply line installed in accordance
with local building codes by a qualified installer
approved and/or licensed as required by the locality.
(In the Commonwealth of Massachusettes installation
must be
performed by a licensed plumber or gas
fitter.)
MILLIVOT GENERATOR
PILOT HOOD
THERMOCOUPLE
5/32" Allen
wrench