GARNET DIRECT VENT ROOM HEATER
250-6443B October 7, 2003 Page 11
R
GARNET DIRECT VENT ROOM HEATER
250-6443B October 7, 2003 Page 12
R
KIT CONTENTS:
Blower motor, housing and snap disc assembly; rheostat (speed control); rheostat nut; knob; screws;
knob position label.
TOOLS REQUIRED
: Short #2 Philips head screwdriver; 11/16" wrench.
The blower is held in place using 4-#6 screws. The scews are already installed in the bottom of the fire box.
1. Remove the (4) screws from the firebox and slide the blower into place from the left side of the stove.
(Fig. 1)
Notice the locations of the pilot assembly tubes and wires. The pilot tubes and wires may need to be moved to prevent
scraping the blower housing.
(Fig. 2)
2
.
Re-use the (4) screws removed from the bottom of the firebox, to install the blower. Install the 2 screws on the right
first, then use the other 2 screws to hold the snap disc in place and support the left side of the blower.
(Fig. 2)
3. Remove the valve access panel by removing the (3) screws that secure it to the right side of stove and sliding it out.
4.
Attach the rheostat to valve access cover and tighten with 11/16 wrench. Attach label showing knob positions on valve
cover. Install the knob on the rheostat.
(Fig. 3)
5. Connect the black and white wires from the blower to the rheostat wires.
(Fig. 4)
6. Re-install the valve access cover.
7. Route power cord away from unit.
DO NOT
route the power cord under or in front of the stove.
FIG. 1
FIG. 2
FIG. 3
BLOWER INSTALLATION
PART #844-9370
Pilot Tubes and Wires
Snap Disc
Mounting Screws
FIG. 4