WARNING! Failure to inspect and maintain the stove may lead to improper combustion and a
potentially dangerous situation. The following procedures are recommended to be completed by a
qualified agency once per year, preferably prior to the burning season.
1. Check or replace ignitor battery. Ignitor requires 1 "AA" 1.5V Battery. (Pg. 42).
2. Check the pilot flame. It should engulf approximately
3/8” of the top of the millivolt generator and engulf
the top of the thermocouple and be 1" above the
burner.
3. Shut off gas to the stove by turning the valve control knob to “OFF” and turning off the manual shutoff valve.
Allow the stove to cool for 15 minutes. Remove the door.
4. Remove the logset (
NOTE
: The logs are fragile). If any log is cracked or deteriorated, replace it when
reinstalling. Check the logs for sooting. A small amount of soot along the bottom of the logs is normal. If
excessive sooting is found, the stove will require adjustment. Contact your dealer.
5. Clean the burner with a soft brush vacuum attachment, (especially the burner holes) and inspect the
following:
a. Check for burner holes that are cracked, plugged or deteriorated.
b. Check the firebox and area around the pilot to make sure there is no warping or damage. If any
problem is found, discontinue use and contact your dealer for service.
6. Re-install the log set. Inspect the door glass, if the door glass is damaged, contact your dealer for a
replacement. Make sure the gasket along the perimeter of the glass contacts the face of the firebox and
forms an airtight seal. If it does not, realign or replace the gasket to ensure an airtight seal. Re-install door.
7. Inspect the area behind the side panels. Check the gas control valve and all of the gas lines. If any damage
is found, discontinue use and contact your dealer for service.
8. Remove any debris or vegetation near the vent termination, outside the house ensuring that the flow of
combustion and ventilation air is not obstructed. Contact your dealer if any sooting or deterioration is found
near the vent termination.
9.
CAUTION!
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
10. Turn on gas and follow Lighting Instructions. The flames should be orange/yellow and not touch the top of the
firebox. If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor the blower
operation.
YEARLY MAINTENANCE PROCEDURES
PILOT HOOD
FLAME
FLAME
MILLIVOLT
GENERATOR
THERMOCOUPLE