NOTE:
In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to
CAN/CSA-B365
.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual
design preference.
5
Venting Systems
NOTE:
In Canada, only a full reline is allowed per
ULC
S628-93, ORD ULC C1482-M1990
.
A. Direct Connect with Outside Air
B. Direct Connect without Outside Air
Outside Air through Rear Wall
Figure 18.1
Figure 18.2
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in
good condition.
• Meets minimum standard of
NFPA 211
•
Factory-built chimney must be a minimum
6 inch (152mm)
UL103 HT
.
WARNING
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
NOTE:
•
Use non-combustible
material around exhaust
vent pipe and seal all
edges with non-flammable
insulation such as
fiberglass, mineral wool or
ceramic material.
•
DO NOT use high
temperature caulking
materials to seal any
edge to prevent future
serviceability.
Summary of Contents for CASTILEI-MBK-C
Page 28: ...28 06 21 7022 801H CASTILE INSERT Date of Service Performed By Description of Service ...
Page 29: ...29 06 21 7022 801H CASTILE INSERT Date of Service Performed By Description of Service ...
Page 30: ...30 06 21 7022 801H CASTILE INSERT Date of Service Performed By Description of Service ...
Page 31: ...31 06 21 7022 801H CASTILE INSERT Date of Service Performed By Description of Service ...