background image

23

February 19, 2020

7037-801B

ARS 

Channel

Reinstall 2 front 

bricks back into 

firebox

ARS Access 

Cover

NOTE:

 The Ash Removal System, must be installed first 

before installing the legs.

C. Leg Kit & ARS Installation

Begin installing the ARS System.

1. 

Remove leg mount brackets packaged inside of firebox 

and set aside.

2. 

Remove the 2 bricks in the front most part of the firebox 

(Figure 21.1 on 

page 21

)

.

3. 

Lay appliance on its back on a protective pad or pallet 

(Figure 21.2 on 

page 21

)

.

4. 

Remove heat shield by loosening the four bolts using 

3/8 open end wrench

 (Figure 21.2 on 

page 21

)

.

5.  Remove 8 nuts that hold the cover plate on 

using a 7/16 socket wrench; discard cover plate 

(Figure 21.2 on 

page 21

)

.

Ash Removel

Drawer

Adapters

Cover 

Plate 

B. Access Cover Handle

Insert Access Cover Handle handle into slot of ARS Cover 

to remove ARS Cover for cleaning ash out of firebox 

(Figure 23.4)

.

Figure 23.1

Figure 23.2

Figure 23.3

Figure 23.4

CHECK GASKET!

•  Verify that the gasket is present and that the glossy 

side is away from firebox bottom.

•  It is important that the gasket is put in correctly for 

sealing capabilities.

WARNING!

Summary of Contents for 4300 Series

Page 1: ...children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide If the information in these instructions is not followed exactly a fire could result ...

Page 2: ...65 4 2 Getting Started 5 A Design and Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies Needed 6 E Inspection of Appliance and Components 6 F Removal of Appliance from Shipping Materials 7 G Install Checklist 8 3 Dimensions and Clearances 9 A Appliance Dimensions 9 B Hearth Protection Requirements 13 C Clearances to Combustibles 15 4 Chimney Systems 16 A Loca...

Page 3: ...ber Number N A EPA Certified Emissions 1 6 grams per hour LHV Tested Efficiency 80 2 HHV Tested Efficiency 74 2 EPA BTU Output 13 200 to 36 800 hr Peak BTU Hour Output 61 700 Vent Size 6 inches Firebox Size 2 26 cubic feet Recommended Log Length 18 inches Fuel Seasoned Cordwood 20 moisture Weighted average LHV Low Heating Value efficiency using Douglas Fir dimensional lumber and data collected dur...

Page 4: ...e without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions WARNING This product and the fuels...

Page 5: ...or on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers 3 A CO detector should be installed i...

Page 6: ...wdriver Electric drill and bits Plumb line Safety glasses Level Tape measure Miscellaneous screws and nails 7 16 socket or wrench 1 2 3 4 in length 6 or 8 self drilling screws Remove appliance and components from packaging and inspect for damage Report to your dealer any parts damaged in shipment Read all the instructions before starting the installation Follow these instructions carefully during ...

Page 7: ... structural boards being careful not to damage product 2 Using 7 16 inch socket or wrench remove and discard the two lag bolts from mounting brackets one on each side that is attaching the appliance to the pallet Figure 7 2 3 Carefully pull appliance off of pallet and lay appliance on back side on a protective surface 4 Reference Appliance Set Up on page 21 for ash removal system leg or pedestal a...

Page 8: ...nce and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and corrective actio...

Page 9: ...Dimensions 26 1 4 in 667mm 30 1 2 in 773mm 15 1 8 in 383mm 11 in 278mm 21 in 533mm 43M ACC C Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID 32 1 4 in 820mm 26 3 8 in 668mm 28 5 8 in 728mm 19 3 4 in 501mm Figure 9 3 Top View 6 3 4 in 170mm 13 1 8 in 333mm 3 5 8 in 92mm ...

Page 10: ... in 533mm 21 in 533mm 11 in 278mm 11 in 278mm 34 1 4 in 868mm 34 1 4 in 868mm 26 in 660mm 26 in 660mm 43ST ACC C WITH PED KIT 43 PEDESTAL KIT Figure 10 2 Side View 26 3 8 in 668mm 28 5 8 in 728mm 19 3 4 in 501mm 35 1 2 in 900mm Figure 10 3 Top View 13 in 330mm 3 1 2 in 87mm 6 3 4 in 170mm ...

Page 11: ... 834mm 25 in 636mm 15 1 8 in 383mm Figure 11 1 Front View 43ST ACC C WITH LEG KIT BK OR LEG KIT NL QUEEN ANNE LEG KIT Figure 11 2 Side View 34 1 8 in 866mm 26 3 8 in 668mm 28 5 8 in 728mm 23 1 4 in 592mm Figure 11 3 Top View 13 in 330mm 3 1 2 in 87mm 6 3 4 in 170mm ...

Page 12: ...12 1 Front View 43ST ACC C WITH TRAD LEG BK TRADITIONAL LEG KIT 26 in 660mm 11 in 278mm 32 7 8 in 834mm 15 1 8 in 383mm 23 3 8 in 595mm 34 1 8 in 866mm 28 5 8 in 728mm 26 3 8 in 668mm 21 5 8 in 550mm Figure 12 3 Top View 13 in 330mm 3 1 2 in 87mm 6 3 4 in 170mm ...

Page 13: ...See exception WARNING Fire Risk Hearth pads must be installed exactly as specified High temperatures or hot embers may ignite concealed combustibles 43M ACC C Figure 13 4 Figure 13 3 Figure 13 5 Figure 13 6 Corner hearth pad dimensions with single wall pipe Corner hearth pad dimensions with double wall pipe These dimensions will vary depending installation Figure 13 1 USA minimum flat wall hearth ...

Page 14: ...pening Fuel loading door USA 54 3 4 in 44 1 4 in 33 1 8 in 15 5 8 in 1 6 i n c h e s f r o m t h e f u e l d o o r o p e n i n g CANADA 1440mm 1252mm 785mm 660mm 4 5 7 m m f r o m t h e f u e l d o o r o p e n i n g USA 54 3 4 in 44 1 4 in 33 1 8 in 15 5 8 in 1 6 i n c h e s f r o m t h e f u e l d o o r o p e n i n g CANADA 1440mm 1252mm 785mm 660mm 4 5 7 m m f r o m t h e f u e l d o o r o p e n...

Page 15: ...2 368 8 203 20 1 2 521 53 1 2 1359 N A 43ST ACC C 10 1 2 267 3 3 4 95 22 559 9 229 2 1 2 64 15 381 49 1 2 1257 N A INSTALLATION ALCOVE DOUBLE WALL PIPE 43M ACC C 16 406 9 3 8 238 27 686 13 7 8 352 N A N A 53 1 2 1359 12 305 43ST ACC C 10 1 2 267 3 3 4 95 25 635 12 305 N A N A 49 1 2 1257 5 127 For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed fa...

Page 16: ...rough the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven ...

Page 17: ...her factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 17 1 and Figure 17 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61cm above any portion o...

Page 18: ... use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the appliance The further your stack...

Page 19: ...himney connector manufacturer Figure 19 2 Instructions 1 Open inside wall at proper height for the chimney connector to entry the masonry chimney Figure 19 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame from 2 x 2 framing lumber to fit...

Page 20: ...d be secured with 3 sheet metal screws Make sure to follow the minimum clearances to combustibles Where passage through the wall or partition of combustible construction is desired in Canada the installation shall conform to CAN CSA B365 Factory built listed chimney connector vented A listed connector vented must be used when installing this appliance in a mobile home The listed connectors must co...

Page 21: ...slot on the left side Figure 21 3 8 Slide the ash door over the 8 screws protruding from the bottom of the appliance Secure with nuts and washers using 7 16 socket wrench Figure 21 3 9 Install ARS latch by sliding latch assembly over 2 threaded studs protruding from the bottom on the left hand side of the appliance Secure by using two nuts use 7 16 socket wrench Figure 21 3 10 Add knob to handle r...

Page 22: ...sh drawer to pedestal base 3 Install ARS access cover inside of ARS Channel that is located inside the firebox Figure 23 2 on page 23 Ash Removal Spacer Insert two bolts through ARS Channel Appliance Gasket and ARS Door Assembly secure with two nuts Figure 22 1 NOTE If installing a floor installation of an outside air kit on a Step Top model with a pedestal assembly you must attach the enclosed co...

Page 23: ...Figure 21 2 on page 21 4 Remove heat shield by loosening the four bolts using 3 8 open end wrench Figure 21 2 on page 21 5 Remove 8 nuts that hold the cover plate on using a 7 16 socket wrench discard cover plate Figure 21 2 on page 21 Ash Removel Drawer Adapters Cover Plate B Access Cover Handle Insert Access Cover Handle handle into slot of ARS Cover to remove ARS Cover for cleaning ash out of f...

Page 24: ...s located inside the firebox Figure 24 4 Figure 24 3 Lay appliance flat on its back on protective padding or pallet Ash Removal Box Leg Brackets Insert 2 bottom screws loosely Align top holes and repeat secure Leveling Legs at Opposite Corners Ash Drawer ARS Access Cover Reinstall 2 front bricks back into firebox Figure 24 4 6 Remove knock out from bottom of firebox by using a hammer Figure 21 2 o...

Page 25: ...h the nuts on the bottom Figure 25 3 and 25 4 CHECK BAFFLE BOARDS CERAMIC BLANKET Verify that the baffle boards and ceramic blanket are in their proper locations It is important that the baffle boards and ceramic blanket are correctly installed for proper burn safety CAUTION NOTE There is a right and a left of the leg brackets Figure 25 1 5 Install six screws to the bottom of the leg brackets Figu...

Page 26: ...or to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake Use the supplied termination cap with a rodent screen Seal between the wall or floor and the pipe with silicone to prevent moisture penetration 5 Floor Installation Alternative In some instances you may not be able to install the flex pipe as show in Figure ...

Page 27: ... need to tear down the handle assembly a few times to gain the correct seal 3 Add square key to door handle shaft may need to use a rubber mallet to ensure key sits firmly into groove of door handle shaft 4 Slide cast iron cam latch over door handle shaft and locking key NOTE DO NOT over tighten locking nut door handle needs to move smoothly Figure 27 1 43M ACC C Install spring handle using a coun...

Page 28: ... the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 28 1 Snap Disc Bracket with Magnet Secure wires with wire tie MANUAL FAN AUTO LOW HIGH OFF MANUAL Over rides the Snap Disc AUTO Fan will turn ON OFF Automatically by the Snap Disc Controls the Fan Speed Shock Risk Do NOT remove grounding prong from ...

Page 29: ... precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure Asphyxiation Risk NEVER INSTALL IN A SLEEPING ROOM Consumes oxygen in the room WARNING CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Do NOT cut through Floor joist wall studs or ceiling t...

Page 30: ...30 February 19 2020 7037 801B 7 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service ...

Page 31: ...31 February 19 2020 7037 801B Date of Service Performed By Description of Service ...

Page 32: ...32 February 19 2020 7037 801B Date of Service Performed By Description of Service ...

Page 33: ...33 February 19 2020 7037 801B Date of Service Performed By Description of Service ...

Page 34: ...7033 262 Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield SRV33271 Y Outside Air Cover Plate Assembly SRV7033 041 Y Door Upgrade Kit UK DRNL FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1 Pkg of 10 25221A 10 Y Button Head 1 4 20 X 5 Pkg of 20 32328 20 Y Nut 2 Wy Side Lock Jam 3 Pkg of 24 226 0100 24 Y Nu...

Page 35: ...ew Flat Head Philips 8 32 x 1 2 Pkg of 12 220 0490 12 Y Washer Sae 3 8 Pkg of 3 ea 832 0990 Y Washer 1 4 Sae Pkg of 24 28758 24 Y Service Parts R 43ST ACC C Beginning Manufacturing Date Jan 2020 Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provide model number...

Page 36: ...g and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 Not...

Reviews: