Page 19
April 19, 2010
4100-I ACT Wood Insert
250-7201F
R
Blower Cord Location & Blower
Control Box With Switch
This insert comes standard with a blower, installed at the
factory with blower cord on right side of insert (as you face
the unit). The blower cord can also be installed on the left
side. Disconnect the cord from right side.
ROUTE WIRES IN
FRONT OF FAN
.
Re-install on the left side. Do not route cord
behind the cooling fan.
Figure 19.2 - Right Side Location
Black
Red
White
Snap Disc
Blower Control
Box with Switch
Cooling Fan
Black
Operating the Blower Control Box with
Snap Disc
1. The blower will turn on/off automatically when set to
AUTO.
2. When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
. Adjust the speed of the fan by turning the HIGH/LOW
knob to the desired setting.
Black
Red
White
Snap Disc
Cooling Fan
Figure 19.3 - Left Side Location
HIGH OFF
LOW
FAN
AUTO
MANUAL
MANUAL: Over-rides
the internal Snap Disc
AUTO: Fan will
turn ON/OFF
automatically and
is controlled by the
internal Snap Disc
Figure 19.1
Figure 19.4