Chapter 2
About the MiniCloset-5c
© COPYRIGHT 2009
Quadlogic Controls Corporation
7
S
PECIFICATIONS
Metering Specifications
Metered Voltage:
Secondary Current Input:
Programmable:
Four Quadrant Consumption &
Delivered and received
Demand for each of the 24 channels:
Programmable Interval Data &
Data and Peak Demand:
Demand Reset:
Real-time data per Phase:
Time-of-Use:
Data Collection Options:
Pulse Datalogger Module (PDM-12):
Distance:
Interrogating Signal Specifications:
120, 208, 220, 230, 240, 277, 347, 380, 400, 416, 480,
600 VAC
Delta or Wye, 50/60 Hz
0.1 Amp or 5 Amp CT inputs available
(8) 3-phase meters, (12) network meters, or (24)
single-phase meters (number of meter points available will
vary by model)
Delivered and received: kW, kVARLeading,
kVARLagging, kVA, Volts-squared hours, and amp-squared
hours
5 minutes to hourly time window (longer time intervals also
available)
Meter total and/or by phase
Programmable to user-determined specific time blocks or
rolling time block demand
Allows local reset of peak demand (kW) register
Voltage, current, phase angle, power factor, THD, watts,
VARs, VA, and frequency
Up to 16 blocks per day available for all metering
parameters (Exception: Pulse input data)
IQ Software
MV-90 TIM Module
ASCII-based, open-data protocol
Open-source data conversion program
Collects data from up to 12 water, gas, or BTU meters
Form A Dry Contact Inputs
PDM connects to MiniCloset-5c via CAT5
Maximum 4 PDM units to a MC-5c (daisy chain)
Total of 48 discrete inputs total
Pulses will count during a power outage
Pulses can be logged in programmable intervals
Power supplied by MiniCloset-5c
Pulse meter to PDM - 300’ max.(18 gauge min.)
All 4 PDM’s to MC-5c - 300’ CAT5 cable
Min. Pulse Width:
Power on - 50 msec.
Power off - 500 msec.*
Max. Pulse Rate:
Power on - 10 pulses/sec max
Power off - 1 pulse/sec max
Peak voltage: 5.5V
Peak current: not applicable
Isolation: The interrogating signal is completely isolated
from the AC line, with isolation barriers rated for
at least 2.5 kV.
Max. signal debounce tolerance: 20 msec.
Summary of Contents for MiniCloset-5c
Page 2: ... COPYRIGHT 2009 Quadlogic Controls Corporation MiniCloset 5c Installation Manual ...
Page 6: ... COPYRIGHT 2009 Quadlogic Controls Corporation 2 ...
Page 16: ...Chapter 3 Parts and Options COPYRIGHT 2009 Quadlogic Controls Corporation 12 ...
Page 27: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 23 ...
Page 28: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 24 ...
Page 33: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 29 ...
Page 34: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 30 ...
Page 39: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 35 ...
Page 40: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 36 ...
Page 45: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 41 ...
Page 46: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 42 ...
Page 51: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 47 ...
Page 52: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 48 ...
Page 57: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 53 ...
Page 58: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 54 ...
Page 78: ... COPYRIGHT 2009 Quadlogic Controls Corporation 74 ...
Page 82: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 78 ...
Page 88: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 84 ...
Page 90: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 86 ...
Page 91: ......
Page 93: ...Dimensional Drawing ...
Page 95: ...Residential Installation Diagrams US ...