EN
QSR SERIES
USER MANUAL - REV000A
10
QSR series
5 - Installation
5.2 -
Closing lid’s preparation and installation
Fig. 7
WARNING:
pay particular attention to avoid interferences between the lid and the hull opening. Too precise contacts
will cause damages to the entire moving system (fig.7).
• Realised the closing lid by keeping on all sides a space
varying from 3 to 5 mm, paying special attention to the
hinge’s side, ensuring that the internal walls are inclined
by 45° so that they don’t hinder the hull’s opening (fig. 7
and 8).
• To obtain the correct opening of the hinge, the surfaces of
hull and lid must be on the same level
(fig.
9).
• The maximum hull thickness must be 35 mm (QSRØ185)
50mm (QSRØ250) (fig. 8).
• Position the angle bracket correctly on the hull
(fig.
10A and 10B - part. A).
Fasten the angle bracket with structural adhesive
(fig.
10B - part. B1 - B2).
Decide whether to fasten the lid bracket to the hull with 3
M8 screws or with resin (fig.
10B - part. C1 - C2).
45°
5 mm
LID
COUNTER FLANGE
Fig. 8
Fig. 10A
LID
HULL
COUNTER FLANGE
ANGLE BRACKET
HINGE
Ø185 45mm
Ø250 60mm
HINGE
SIDE
Ø185 26mm
Ø250 36mm
1
Fig. 10B
A
B1
B2
C1
STRUCTURAL
ADHESIVE
GRP LAYERS
N 3 M8 SCREWS
ANGLE BRACKET
COUNTER FLANGE
C2
ANGLE BRACKET
ANGLE BRACKET
ANGLE BAR
Fig. 9
LID
LID’S
BRACKET
HULL
HINGE