background image

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11.X / BFG

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11.X / BFG

22

23

6 Faults and defects

Danger! 
Risk of fatal injury due to electric shock!

  Do not attempt to fix any problems yourself (e.g., glass cracks, 

damaged cables).

  Please contact an installer or Qcells Technical Customer 

Service Department.

7 Disposal

  Do not disconnect modules by yourself.
 Please commission a trade specialist.
  Dispose of modules in accordance with the local disposal 

regulations.

8 Maintenance and cleaning

Qcells solar modules are known for a long operating life and 
minimal maintenance effort and expense. Dirt and grime are 
usually washed away by rain. If the module is fully or partially 
shaded by dirt or debris (e.g., plants, bird droppings), it needs 
to be cleaned to prevent a loss of performance.

Maintenance

  The PV system has to be inspected regularly by certified 

personnel

  The time intervals and extent of the inspection can depend 

on local circumstances (e.g. salt, ammonia content in the air, 
high humidity etc.). The customer / operator must inform himself 
about time intervals and extend of necessary inspections.

  Inspections have to be performed especially after extraordinary 

events (e.g. storm, hail, high snow loads etc.)

  During the inspections it has to be checked that the 

components are secure, undamaged and clean

Cleaning

WARNING! 
Risk of injury due to hot and live modules!

  Only clean modules that have cooled down.
  Do not carry or wear any electrically conductive parts.

WARNING! 
Risk of falling due to unsecured access!

  Never access the installation area alone or without taking 

adequate security precautions.

  Please commission a trade specialist.

NOTE! 
Module surface damage may occur!

  Remove snow and ice carefully without force (e.g. with a very 

soft broom).

  Do not scratch off dirt.
  Module cleaning has to be done by qualified personnel 

according to the state of the art and taking into account all 
relevant safety issues and general product properties, e.g., but 
not restricted to:

 

electrical safety

 

mechanical stability (load limits depending on the actual 
mounting options)

 

chemical suitability (no effect to any of the module‘s 
components, e.g. cable, connector, silicone)

 

no abrasive materials.

NOTE! 
Dust and dirt are abrasive materials!

  The situation for each individual project (or type of dirt) must 

always be professionally evaluated.

  Wrong cleaning may cause damages such as, but not limited 

to, damages to the glass surface (e.g. scratches) and AR 
coating, power loss, delamination, loss of frame-to-laminate 
bond, reduced snow and wind load capability etc.

Apart from the above, each customer is free to choose the 
method of cleaning. However, possible damages, caused by 
the cleaning or related to the cleaning tools or agents shall 
not be covered by the module‘s Product and Performance 
Warranty. Therefore it is recommended to use only the tools 
and agents which have already been successfully tested and 
used with PV modules, to prevent possible damage.

Isopropyl alcohol (IPA) can be used selectively to remove 
stubborn dirt and stains within one hour after emergence.

Note! Module damage may occur!

  Do not clean modules with water if there is a risk of 

frost.

  Free the substructure from any dirt and debris (leaves, 

bird nests, etc.).

Summary of Contents for Q.PEAK DUO XL-G11.X / BFG Series

Page 1: ...Installation and operation manual Q PEAK DUO XL G11 X BFG solar module series...

Page 2: ...d solar module operator are responsible for compliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the install...

Page 3: ...ALLATION OR CONFIGURATION IMPROPER MAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION Attention This marking indicates that this product should not be disposed of with other household waste with...

Page 4: ...the following applications Operating temperatures from 40 F to 185 F Pull loads and push loads according to chapter 2 3 Test Load in accordance with IEC 61215 and Design Load 1 5 in accordance with U...

Page 5: ...s FB1 4 mounting slots 20 508 FB2 4 mounting slots 20 508 mFB2 20 508 Tracker installation on mounting points TB1a 39 7 1008 TB1b 32 813 39 7 1008 TB2a 20 or 32 or 39 7 508 or 813 or 1008 TB2b 32 813...

Page 6: ...acer allowed between the module and substructure CL1a FB1 These mounting options are not recommended as mounting rails will cast shade on the module rear side FB1 FB2 TB1a TB1b TB2a TB2b mFB2 Use M8 c...

Page 7: ...erter into account when determining the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks o...

Page 8: ...upright and horizontally as shown Note Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 Installation 3 2 Pr...

Page 9: ...may result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire op...

Page 10: ...of fatal injury due to electric shock Electrical work may only be performed by qualified and skilled personnel see page 3 Ensure correct polarity 4 Electrical Connection 4 3 Connection of modules Use...

Page 11: ...0 0 8 0 0 08 0 79 0 47 0 08 Option A Use of a grounding lug A listed grounding lug can be bonded to the frame using the grounding holes pre drilled in the frame These holes are marked with a ground sy...

Page 12: ...Risk of falling due to unsecured access Never access the installation area alone or without taking adequate security precautions Please commission a trade specialist NOTE Module surface damage may occ...

Page 13: ...nstallation manual solar modules Q PEAK_DUO_XL G11 X BFG_modules_series_2022 07_Rev01_NA HANWHA Q CELLS AMERICA INC 400 Spectrum Center Drive Suite 1400 Irvine CA 92618 USA EMAIL WEB TEL hqc inquiry q...

Reviews: