4
5
INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – HANWHA Q CELLS – NA
INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – HANWHA Q CELLS – NA
For the electrical data and additional information of the solar modules please refer to the respective currently valid data sheets available at
www.q-cells.com.
PRODUCT LINE
Q.PEAK DUO-G5.X
Q.PEAK DUO BLK-G5.X
Cell type
Q.ANTUM
Length [
in
(mm)]
66.3 (1685)
Width [
in
(mm)]
39.4 (1000)
Height [
in
(mm)]
1.26 (32)
Area [yd² (m²)]
2 (1.69)
Weight [lbs (kg)]
41.2 (18.7)
Max. system voltage V
SYS
[V]
1000
Max. series fuse rating [A]
20
Permissible operating
temperature range [°F (°C)]
–40 to +185 (–40 to +85)
Junction box protection class
IP67 with bypass diode
Connector protection class
IP68 and IP65
Fire protection class
C, Type 1
Push load [Pa]
1
5,400
Pull load [Pa]
1
4,000
Certificates
UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2)
1
see page 9 et sqq.;
IEC 61730 (Ed.1) Application Class A
1
‘Test Load’ in accordance with IEC 61215 and ‘Design Load
×
1.5’ in accordance with UL 1703
Validity
These instructions are only valid for crystalline solar modules from
Q CELLS as specified at chapter „2.1 Technical specifications“.
Q CELLS assumes no liability for damage resulting from failure to
observe these instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Q CELLS assumes no liability on the basis of these instructions.
Q CELLS is only liable in the context of contractual agreements or
in the context of accepted guarantees. Q CELLS accepts no other
responsibility for the functionality and safety of the modules.
Ä
Please observe the instructions for any other system components
that may be part of the complete solar power system. It may be
necessary to carry out a structural analysis for the entire project.
Ä
If your questions are not satisfactorily answered in the manual,
please contact your system supplier.
Additional information can be found on our website at:
www.q-cells.com.
Information for the Operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and energy
providers regarding regulations and permit requirements prior
to installation of the solar power system. Your financial success
depends on the fulfillment of these requirements.
Other applicable documents
This installation manual is only valid in combination with the
following technical information.
DOCUMENT TYPE
Product data sheet
Packaging and transport information
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER
INSTALLATION OR CONFIGURATION, IM PROPER MAINTENANCE,
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.
1 INTRODUCTION
2.1 Technical specifications
2 PLANNING
Fig. 1:
External dimensions (in inch (mm)) and components for Q.PEAK DUO-G5.X, Q.PEAK DUO BLK-G5.X,
NA
DETAIL A 0.630" (16mm)
0.335" (8.5mm)
0.965" (24.5mm)
38.58" (980mm)
66.3" (1685mm)
4 × Mounting slots (DETAIL A)
Frame
39.4" (1000mm)
37.44" (951mm)
1.26" (32mm)
8 × Drainage holes
13.9“ (352.5mm)
6 × Grounding points ø
0.177" (
4,5mm)
≥ 43.3“ (≥
1100
mm)
≥ 43.3“ (≥
1100
mm)