INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – HANWHA Q CELLS – NA
INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – HANWHA Q CELLS – NA
2 PLANNING
2.3 Mounting options
Module Selection
For detailed key electrical data, please refer to the product data
sheet for the respective product.
Ä
For maximum energy yields, mismatches of specified electric
current (I
MPP
) of more than 5 % should be avoided for all modules
connected in series.
Safety Factor
During normal operation, a module may generate a greater current
and / or higher voltage than that determined under standardized test
conditions. Accordingly, the values of I
SC
and V
OC
marked on the
module should be multiplied by a facot of 1.25 when determining:
•
the component voltage ratings,
•
conductor ampacities,
•
fuse sizes,
•
size of controls connected to the PV output.
Refer to Section 690-8 of the National Electrical Code for an
additional multiplying factor of 125 percent (80 percent derating)
which might be applicable.
Ä
Please follow the valid national guidelines for the installation
of electrical systems (refer to section 690-8 of the NEC for an
additional multiplying factor of 125 percent [80 percent derating]
which may be applicable).
Series Connection
Connection of modules in series is only permitted up to the
maximum system voltage as listed in the applicable data sheet.
Ä
Take into account all possible operating situations and all relevant
technical norms and regulations when designing the system.
This will ensure that the maximum system voltage, including all
necessary safety margins, is not exceeded.
Ä
Take the voltage limit of the inverter into account when determining
the maximum number of modules in the string.
Parallel Connection
Modules may be damaged by the occurrence of reverse currents
(caused by module defects, ground leaks, or defective insulation).
Ä
Ensure that the maximum reverse current load capacity indicated
in the data sheet is met.
In order to limit reverse currents that may occur, we recommend
using the following safety options:
1) Layout with a limited number of parallel connected strings :
Without undertaking further current blocking measures, a maximum
of two module strings may be operated in parallel on a single
inverter or MPP tracker.
2) Layout with string fuses :
Place fuses for each string of modules at the plus and minus ends.
Observe the maximum permitted number of strings as indicated
in the specifications provided by the respective string fuse manu
-
facturer and the technical guidelines.
NOTE!
When installing different product versions, the lowest minimum
permitted reverse current load capacity applies.
Inverters
Inverters with or without transformers may be used.
2.4 Electrical layout
2 PLANNING
Specifications
MODULE TYPE
MOUNTING
OPTION
POSITION OF CLAMPS* [IN (MM)]
TEST LOAD
PUSH/PULL**
[PA]
DESIGN LOAD
PUSH/PULL**
[PA]
SAFETY
FACTOR
Q.PEAK DUO-G5.X
Q.PEAK DUO BLK-G5.X
CL1 / CL3
9.84 - 17.72 (250 - 450)
5400/4000
3600/2670
1.5
FB1 / FB2
13.58 (345)
IP1
-
CL1
0 - 9.84 (0 - 250)
17.72 - 21.65 (450 - 550)
2400/2400
1600/1600
CL2
0 - 9.84 (0 - 250)
CL4
0- 11.81 (0 - 300)
CL5
short side: 0 - 9.84 (0 - 250)
long side: 11.81 - 15.75 (300 - 400)
4000/4000
2670/2670
MODULE TYPE
MOUNTING
OPTION
POSITION OF CLAMPS* [IN (MM)]
TEST LOAD
PUSH/PULL***
[PA]
DESIGN LOAD
PUSH/PULL***
[PA]
SAFETY
FACTOR
Q.PEAK DUO-G5.X
Q.PEAK DUO BLK-G5.X
IP2
-
2400/2200
1600/1470
1.5
*
**
***
Distance between outer edge of module and middle of the clamp.
Loads according to IEC 61215-2:2016 and UL 1703.
Test sequence according to IEC 61215-2:2016.
ATTENTION
Ä
The loads in the table are related to the mechanical stability of the solar modules. The mechanical stability of the mounting system
including clamps has to be evaluated by the system supplier. The system installer is responsible for the determination of location-
specific load requirements.
Ä
Ensure, that the subconstruction does not touch the junction box (even under load).
Ä
Ensure, that the connection cables of the junction box do not run between laminate and mounting rails.
Ä
Ensure, minimum support depth of 15 mm on the back side of the module for IP2, CL2 and CL4. Ensure minimum support depth
of 10 mm on the front side of the module for IP2.
Ä
Module bend under loads. Therefore, sharp objects (e.g. screws) must not be mounted near the module backside.
Ä
Use M8 corrosion-proof screws and washers (diameter
≥
15.8 mm or
≥
0.62 in) for FB1 and FB2 mounting.