Use solar cables for the connection at the junction 
box outlet. 

 

Ä

Use the same, inverter-compatible plugs.

SOLAR

NOTE

! Module damage may occur!

 

Ä

Ensure that the cabling is not under stress.

 

Ä

Ensure that the cables do not run between 
module and mounting rail or structure 
(danger of pinch).

 

Ä

Do not connect modules with different orientations 
or angles of inclination in the same string.

 

Ä

Ensure for a tight connection between the plugs. 
Plugs click together audibly.

EN

click

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Ensure that all electrical components are in a 
proper, dry, and safe condition.

4.3  Connection of modules

ELECTRICAL CONNECTION

 

Ä

To avoid complex cabling arrangements, it is often 
advantageous to rotate some modules 180

˚

.

 

Ä

Module orientation can clearly be identified from 

the front side by the serial number and barcode 
labelled behind the module glass on the side with 
negative connection cable.

Inverter

180°

180°

 

Ä

Ensure that all necessary safety and functional 
tests have been carried out according to applicable 
standards.

NOTE

! Module damage may occur!

 

Ä

Ensure that the plug connections are secured away 
from any water-channelling surface.  

 

Ä

Integrate the system into the existing lightening 
protection system in accordance with the 
applicable local regulations.

WARNING

! Fire Risk!

 

Ä

Do not use light concentrators (e.g. mirrors or 
lenses).

 

Ä

Ensure that the cabling is not exposed and/or 
hanging and is protected from dirt, moisture and 
mechanical friction.

4.4  After installation

ELECTRICAL CONNECTION

Summary of Contents for Q.PEAK DUO BLK-G5 series

Page 1: ...Valid for North America Q PEAK DUO G5 X SOLAR MODULE SERIES INSTALLATION AND OPERATION MANUAL ...

Page 2: ...ou check the results of said procedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both Imperial and U S units for example inches are shown metric units are definitive References to Data Sheet or Module Data Sheet refer to the Module Data Sheet applicable to t...

Page 3: ... of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Ä Ä Please observe the instructions for any other system components that may be part of the complete solar power system It may be necessary to carry out a structural analysis for the entire project Ä Ä If your questions are not satisfactorily answered in the manual please contact your sy...

Page 4: ...ar ventilation of the module Guarantees long term stability Avoid of different metals to prevent contact corrosion Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion applied to on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Us...

Page 5: ...r of parallel connected strings Without undertaking further current blocking measures a maximum of two module strings may be operated in parallel on a single inverter or MPP tracker 2 Layout with string fuses Place fuses for each string of modules at the plus and minus ends Observe the maximum permitted number of strings as indicated in the specifications provided by the respective string fuse man...

Page 6: ...ely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your vendor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Do not drop modules NOTE Module damage may occur Ä Ä Only make modifications to the module which have been confirmed in writing by Q...

Page 7: ...insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not modify the module e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 0 39 in 10 mm between two modules along the short side and 0 20 in 5 mm along the long side 0 39 in 10mm 0 2 0 i n 5 m m Option 2 Ä Ä Install t...

Page 8: ...rvals specified by the inverter manufacturer after switching off the inverter DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Do not remove bypass diodes DANGER Risk of fatal injury due to electric shock Ä Ä Never touch live contacts with bare hands Ä Ä Cover connectors by suitable protective caps until installation DANGER Risk of fatal injury due to electric ...

Page 9: ...nd safe condition 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä To avoid complex cabling arrangements it is often advantageous to rotate some modules 180 Ä Ä Module orientation can clearly be identified from the front side by the serial number and barcode labelled behind the module glass on the side with negative connection cable Inverter 180 180 Ä Ä Ensure that all necessary safety and fu...

Page 10: ...ductor Aluminum Frame Screw Stainless Steel are marked with a ground symbol as shown below on the frame section drawing To install the grounding lug follow the specified instructions of the manufacturer The grounding lug should be made of stainless steel or tin plated metals such as aluminum to avoid corrosion The grounding lug should be attached to the frame grounding hole using a stainless steel...

Page 11: ...ve cooled down Ä Ä Do not carry or wear any electrically conductive parts WARNING Risk of falling due to unsecured access Ä Ä Never access the installation area alone or without taking adequate security precautions Ä Ä Please commission a trade specialist NOTE Module surface damage may occur Ä Ä Remove snow and ice without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt...

Page 12: ...C 300 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 949 748 59 96 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS Installation manual solar modules DUO G5 X_2017 10_Rev01_NA ...

Reviews: