Installation Guide / ComT 2.0: 5°, 10° and 15°
29
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
10
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 5 and 10 degrees COMT
Type of Rail
ER-R-T50
Type of Interface
S-MT/240 (MT – Rail support)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 10° <
α
< 20°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.35
0.90
0.68
0.45
1.35
0.90
0.68
0.45
1.28
0.85
0.64
0.43
1.23
0.82
0.61
0.41
1.18
0.79
0.59
0.39
B
1.14
0.76
0.57
0.38
1.14
0.76
0.57
0.38
1.08
0.72
0.54
0.36
1.04
0.69
0.52
0.35
1.00
0.67
0.50
0.33
C
0.99
0.66
0.49
0.33
0.69
0.46
0.35
0.23
0.66
0.44
0.33
0.22
0.42
0.28
0.21
0.14
0.40
0.27
0.20
0.13
D
0.57
0.38
0.29
0.19
0.57
0.38
0.29
0.19
0.35
0.23
0.18
0.12
0.33
0.22
0.17
0.11
0.31
0.21
0.16
0.10
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.31
0.87
0.65
0.44
1.26
0.84
0.63
0.42
1.20
0.80
0.60
0.40
1.17
0.78
0.58
0.39
1.13
0.75
0.56
0.38
B
1.10
0.73
0.55
0.37
1.06
0.71
0.53
0.35
1.01
0.68
0.51
0.34
0.99
0.66
0.49
0.33
0.95
0.64
0.48
0.32
C
0.96
0.64
0.48
0.32
0.65
0.43
0.32
0.22
0.62
0.41
0.31
0.21
0.40
0.26
0.20
0.13
0.38
0.25
0.19
0.13
D
0.54
0.36
0.27
0.18
0.52
0.34
0.26
0.17
0.32
0.22
0.16
0.11
0.31
0.21
0.15
0.10
0.30
0.20
0.15
0.10
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.26
0.84
0.63
0.42
1.18
0.79
0.59
0.39
1.14
0.76
0.57
0.38
1.11
0.74
0.55
0.37
1.08
0.72
0.54
0.36
B
1.07
0.71
0.53
0.36
1.00
0.67
0.50
0.33
0.96
0.64
0.48
0.32
0.95
0.63
0.47
0.32
0.92
0.61
0.46
0.31
C
0.93
0.62
0.46
0.31
0.60
0.40
0.30
0.20
0.57
0.38
0.29
0.19
0.37
0.25
0.19
0.12
0.36
0.24
0.18
0.12
D
0.52
0.34
0.26
0.17
0.47
0.31
0.23
0.16
0.30
0.20
0.15
0.10
0.29
0.19
0.14
0.10
0.28
0.19
0.14
0.09
11
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 15 degrees COMT
Type of Rail
ER-R-T50
Type of Interface
S-MT/240 (MT – Rail support)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 0° <
α
< 10°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.47
0.98
0.73
0.49
1.47
0.98
0.73
0.49
1.36
0.91
0.68
0.45
1.31
0.87
0.66
0.44
1.26
0.84
0.63
0.42
B
1.27
0.85
0.64
0.42
1.27
0.85
0.64
0.42
1.22
0.81
0.61
0.41
1.16
0.77
0.58
0.39
1.11
0.74
0.55
0.37
C
1.11
0.74
0.55
0.37
0.60
0.40
0.30
0.20
0.57
0.38
0.29
0.19
0.22
0.14
0.11
0.07
0.22
0.14
0.11
0.07
D
0.51
0.34
0.26
0.17
0.51
0.34
0.26
0.17
0.19
0.13
0.10
0.06
0.19
0.13
0.10
0.06
0.18
0.12
0.09
0.06
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.42
0.94
0.71
0.47
1.36
0.91
0.68
0.45
1.31
0.87
0.66
0.44
1.26
0.84
0.63
0.42
1.21
0.80
0.60
0.40
B
1.22
0.81
0.61
0.41
1.16
0.77
0.58
0.39
1.16
0.77
0.58
0.39
1.11
0.74
0.55
0.37
1.05
0.70
0.53
0.35
C
1.05
0.70
0.53
0.35
0.57
0.38
0.29
0.19
0.54
0.36
0.27
0.18
0.21
0.14
0.10
0.07
0.21
0.14
0.10
0.07
D
0.51
0.34
0.26
0.17
0.48
0.32
0.24
0.16
0.18
0.12
0.09
0.06
0.18
0.12
0.09
0.06
0.18
0.12
0.09
0.06
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.36
0.91
0.68
0.45
1.26
0.84
0.63
0.42
1.21
0.80
0.60
0.40
1.21
0.80
0.60
0.40
1.15
0.77
0.58
0.38
B
1.22
0.81
0.61
0.41
1.11
0.74
0.55
0.37
1.11
0.74
0.55
0.37
1.05
0.70
0.53
0.35
1.05
0.70
0.53
0.35
C
1.05
0.70
0.53
0.35
0.54
0.36
0.27
0.18
0.51
0.34
0.26
0.17
0.21
0.14
0.10
0.07
0.19
0.13
0.10
0.06
D
0.48
0.32
0.24
0.16
0.45
0.30
0.23
0.15
0.18
0.12
0.09
0.06
0.17
0.11
0.08
0.06
0.17
0.11
0.08
0.06
- Certification -