Installation Guide / ComT 2.0: 5°, 10° and 15°
35
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
20
Note 4. Standard screws shipped for Tin Roof Interfaces
Metal Purlins/Battens
Fasteners to use
1.2 mm - 2.4 mm
Buildex- 14 - 11 x 70 Hex Head Zips with 16 mm Aluminium
Bonded Washer or a screw that has an equal or a higher
pullout capacity.
Wood Purlins and Rafters
Fasteners to be used
Timber F7 (Pine) and Timber 17
(Hardwood). 25 mm, 30 mm and
35 mm embedment into the timber
Buildex- 14 - 11 x 70 Hex Head Zips with 16 mm Aluminium
Bonded Washer or a screw that has an equal or a higher
pullout capacity.
Note 5. Fixing spacing to be reduced on increased according to the purlin thickness as per below:
Purlin Thickness
From 1.2mm to
1.49mm
From 1.5 mm to
1.89 mm
From 1.9 to 2.4 mm
Reduction of 60%
Reduction of 30%
Spacings remain the
same
Tophats from 0.42 mm to 0.75 mm are not included in this certificate. Contact Clenergy
if your project has the aforementioned parameters.
Note 6. Fixing spacing to be reduced to timber purlins as per below:
Batten type
25 mm
30 mm
35 mm
Timber F7
Reduction of 55%
Reduction of 45%
Reduction of 40%
Timber F17
Spacings remain
the same
Spacings remain
the same
Spacings remain the
same
Note 7. This certificate only covers the assessment of the Clenergy PV mounting system, including
the components listed on note 4 and 8. Assessment of the roof structure, PV panels and other fixings
are to be checked by the installer/contractor, if necessary.
Note 8. The following components are satisfied for use according to AS/NZS 1664.1:1997-Amdt
1:1999 and AS/NZS 1170.2:2011 Amdt 4-2016.
Components
Part No.
Description
ECO-Rail
All ECO rails
All ECO rails
Splice
ER-SP-ECO
PV-ezRack Splice for ECO
rail