Installation Guide / ComT 2.0: 5°, 10° and 15°
26
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
4
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 5 and 10 degrees COMT
Type of Rail
ER-R-ECO (ECO Rail) and all other ECO rails
Type of Interface
ER-I-05 (Tin Interface)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 0° <
α
< 10°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.97
1.31
0.99
0.66
1.97
1.31
0.99
0.66
1.82
1.21
0.91
0.61
1.71
1.14
0.86
0.57
1.62
1.08
0.81
0.54
B
1.62
1.08
0.81
0.54
1.62
1.08
0.81
0.54
1.52
1.01
0.76
0.51
1.45
0.97
0.73
0.48
1.38
0.92
0.69
0.46
C
1.37
0.91
0.68
0.46
0.97
0.64
0.48
0.32
0.91
0.61
0.46
0.30
0.58
0.39
0.29
0.19
0.56
0.37
0.28
0.19
D
0.80
0.53
0.40
0.27
0.80
0.53
0.40
0.27
0.51
0.34
0.25
0.17
0.49
0.33
0.24
0.16
0.46
0.31
0.23
0.15
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.87
1.24
0.93
0.62
1.76
1.17
0.88
0.59
1.66
1.11
0.83
0.55
1.60
1.07
0.80
0.53
1.53
1.02
0.76
0.51
B
1.55
1.03
0.77
0.52
1.49
0.99
0.74
0.50
1.41
0.94
0.71
0.47
1.37
0.91
0.68
0.46
1.31
0.87
0.65
0.44
C
1.32
0.88
0.66
0.44
0.89
0.60
0.45
0.30
0.86
0.57
0.43
0.29
0.55
0.37
0.28
0.18
0.53
0.35
0.27
0.18
D
0.77
0.52
0.39
0.26
0.74
0.50
0.37
0.25
0.48
0.32
0.24
0.16
0.46
0.31
0.23
0.15
0.45
0.30
0.22
0.15
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.78
1.18
0.89
0.59
1.62
1.08
0.81
0.54
1.54
1.03
0.77
0.51
1.50
1.00
0.75
0.50
1.45
0.97
0.73
0.48
B
1.49
0.99
0.74
0.50
1.38
0.92
0.69
0.46
1.33
0.88
0.66
0.44
1.29
0.86
0.65
0.43
1.26
0.84
0.63
0.42
C
1.28
0.85
0.64
0.43
0.83
0.56
0.42
0.28
0.80
0.54
0.40
0.27
0.52
0.35
0.26
0.17
0.51
0.34
0.26
0.17
D
0.75
0.50
0.38
0.25
0.70
0.46
0.35
0.23
0.45
0.30
0.22
0.15
0.44
0.29
0.22
0.15
0.43
0.29
0.21
0.14
5
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 5 and 10 degrees COMT
Type of Rail
ER-R-ECO (ECO Rail) and all other ECO rails
Type of Interface
ER-I-05 (Tin Interface)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 10° <
α
< 20°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.21
0.80
0.60
0.40
1.21
0.80
0.60
0.40
1.15
0.77
0.58
0.38
1.11
0.74
0.55
0.37
1.05
0.70
0.53
0.35
B
1.02
0.68
0.51
0.34
1.02
0.68
0.51
0.34
0.96
0.64
0.48
0.32
0.93
0.62
0.46
0.31
0.89
0.59
0.45
0.30
C
0.89
0.59
0.45
0.30
0.59
0.40
0.30
0.20
0.56
0.38
0.28
0.19
0.36
0.24
0.18
0.12
0.34
0.23
0.17
0.11
D
0.46
0.30
0.23
0.15
0.46
0.30
0.23
0.15
0.26
0.18
0.13
0.09
0.24
0.16
0.12
0.08
0.21
0.14
0.10
0.07
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.17
0.78
0.59
0.39
1.13
0.75
0.56
0.38
1.08
0.72
0.54
0.36
1.04
0.70
0.52
0.35
1.01
0.67
0.50
0.34
B
0.98
0.65
0.49
0.33
0.95
0.63
0.47
0.32
0.91
0.61
0.45
0.30
0.88
0.59
0.44
0.29
0.86
0.57
0.43
0.29
C
0.86
0.57
0.43
0.29
0.55
0.37
0.28
0.18
0.53
0.35
0.26
0.18
0.34
0.22
0.17
0.11
0.30
0.20
0.15
0.10
D
0.41
0.28
0.21
0.14
0.37
0.25
0.19
0.12
0.22
0.15
0.11
0.07
0.20
0.14
0.10
0.07
0.18
0.12
0.09
0.06
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.13
0.75
0.56
0.38
1.05
0.70
0.53
0.35
1.02
0.68
0.51
0.34
1.00
0.67
0.50
0.33
0.97
0.65
0.49
0.32
B
0.95
0.64
0.48
0.32
0.89
0.59
0.45
0.30
0.86
0.58
0.43
0.29
0.85
0.56
0.42
0.28
0.82
0.55
0.41
0.27
C
0.83
0.55
0.41
0.28
0.52
0.34
0.26
0.17
0.47
0.31
0.23
0.16
0.29
0.19
0.15
0.10
0.27
0.18
0.14
0.09
D
0.38
0.25
0.19
0.13
0.31
0.21
0.16
0.10
0.19
0.13
0.09
0.06
0.18
0.12
0.09
0.06
0.16
0.11
0.08
0.05
- Certification -