Installation Guide / ComT 2.0: 5°, 10° and 15°
30
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
12
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 15 degrees COMT
Type of Rail
ER-R-T50
Type of Interface
S-MT/240 (MT – Rail support)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 10° <
α
< 20°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.16
0.77
0.58
0.39
1.16
0.77
0.58
0.39
1.11
0.74
0.55
0.37
1.05
0.70
0.53
0.35
1.00
0.66
0.50
0.33
B
1.00
0.66
0.50
0.33
1.00
0.66
0.50
0.33
0.94
0.63
0.47
0.31
0.89
0.59
0.44
0.30
0.89
0.59
0.44
0.30
C
0.83
0.55
0.42
0.28
0.53
0.35
0.26
0.18
0.53
0.35
0.26
0.18
0.21
0.14
0.11
0.07
0.20
0.13
0.10
0.07
D
0.44
0.30
0.22
0.15
0.44
0.30
0.22
0.15
0.18
0.12
0.09
0.06
0.17
0.11
0.08
0.06
0.14
0.09
0.07
0.05
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.11
0.74
0.55
0.37
1.11
0.74
0.55
0.37
1.05
0.70
0.53
0.35
1.00
0.66
0.50
0.33
1.00
0.66
0.50
0.33
B
0.94
0.63
0.47
0.31
0.89
0.59
0.44
0.30
0.89
0.59
0.44
0.30
0.83
0.55
0.42
0.28
0.83
0.55
0.42
0.28
C
0.83
0.55
0.42
0.28
0.49
0.33
0.25
0.16
0.49
0.32
0.24
0.16
0.20
0.13
0.10
0.07
0.19
0.13
0.09
0.06
D
0.42
0.28
0.21
0.14
0.39
0.26
0.19
0.13
0.15
0.10
0.08
0.05
0.14
0.09
0.07
0.05
0.14
0.09
0.07
0.05
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.11
0.74
0.55
0.37
1.00
0.66
0.50
0.33
1.00
0.66
0.50
0.33
1.00
0.66
0.50
0.33
0.94
0.63
0.47
0.31
B
0.94
0.63
0.47
0.31
0.89
0.59
0.44
0.30
0.83
0.55
0.42
0.28
0.83
0.55
0.42
0.28
0.83
0.55
0.42
0.28
C
0.83
0.55
0.42
0.28
0.47
0.31
0.23
0.16
0.44
0.30
0.22
0.15
0.19
0.12
0.09
0.06
0.18
0.12
0.09
0.06
D
0.39
0.26
0.19
0.13
0.32
0.21
0.16
0.11
0.14
0.09
0.07
0.05
0.12
0.08
0.06
0.04
0.12
0.08
0.06
0.04
13
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 15 degrees COMT
Type of Rail
ER-R-T50
Type of Interface
S-MT/240 (MT – Rail support)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 20° <
α
< 25°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
0.91
0.60
0.45
0.30
B
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
0.85
0.56
0.42
0.28
0.80
0.53
0.40
0.27
0.75
0.50
0.38
0.25
C
0.73
0.48
0.36
0.24
0.42
0.28
0.21
0.14
0.39
0.26
0.19
0.13
0.15
0.10
0.08
0.05
0.14
0.09
0.07
0.05
D
0.28
0.19
0.14
0.09
0.28
0.19
0.14
0.09
0.11
0.07
0.05
0.04
0.11
0.07
0.05
0.04
0.09
0.06
0.05
0.03
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
0.97
0.64
0.48
0.32
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
B
0.85
0.56
0.42
0.28
0.82
0.55
0.41
0.27
0.77
0.52
0.39
0.26
0.74
0.50
0.37
0.25
0.71
0.47
0.35
0.24
C
0.67
0.44
0.33
0.22
0.35
0.24
0.18
0.12
0.32
0.21
0.16
0.11
0.14
0.09
0.07
0.05
0.12
0.08
0.06
0.04
D
0.28
0.19
0.14
0.09
0.25
0.17
0.12
0.08
0.09
0.06
0.05
0.03
0.09
0.06
0.05
0.03
0.09
0.06
0.05
0.03
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
0.97
0.64
0.48
0.32
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
0.85
0.56
0.42
0.28
B
0.83
0.56
0.42
0.28
0.75
0.50
0.38
0.25
0.71
0.48
0.36
0.24
0.67
0.44
0.33
0.22
0.67
0.44
0.33
0.22
C
0.61
0.40
0.30
0.20
0.32
0.21
0.16
0.11
0.28
0.19
0.14
0.09
0.12
0.08
0.06
0.04
0.11
0.07
0.05
0.04
D
0.25
0.17
0.12
0.08
0.21
0.14
0.11
0.07
0.09
0.06
0.05
0.03
0.08
0.05
0.04
0.03
0.08
0.05
0.04
0.03
- Certification -