Plumbing System
5-1
Section 5
C238
Plumbing System
5.1 Fresh Water System
(Optional)
General
The fresh water system consists of a potable
water tank, distribution lines and a distribu-
tion pump. The pump is equipped with an
automatic pressure switch and is located in
the forward bilge area. It can be accessed
through the forward access panel in the
head unit. An in-line strainer located near
the pump protects the system from debris.
The tank is filled through a labeled deck fill
located on the port side, forward gunwale
area.
DO NOT confuse other deck fill with fresh
water fill. If toxic fluids or fuel is added to
fresh water tank, the system will be contami-
nated. DO NOT attempt to pump fuel out;
this system is not designed to pump fuel.
Fuel must be removed by qualified person-
nel only. Fuel in the fresh water systems will
also require replacement of that system and/
or many components.
Operation
Fill the water supply tank slowly through the
FRESH WATER FILL deck plate. After filling
tank, partially open all faucets. Turn on
“Fresh Water System” switch at the helm.
Allow the pump to run until all of the air is
purged from the system and a steady stream
of water is flowing from each outlet. Next,
turn off the faucets one by one. As the pres-
sure builds, the pump will automatically shut
off.
When properly primed and activated, the
water system will operate like the water sys-
tem in a home. An automatic pressure sen-
sor keeps the system pressurized. If the
system has been recently filled or has not
been used for an extended period, air may
accumulate at the pump and the system
may have to be re-primed. Whenever the
boat is left unattended, turn the fresh water
system switch "OFF."
5.2 Raw Water Washdown
The raw water washdown system pump is
supplied by hoses connected to a ball valve
and a thru-hull fitting located in the bilge,
accessed under the mechanical hatch.
Operation
Make sure the ball valve is open before
attempting to operate the raw water wash-
down system. The pump is activated by the
washdown switch located on the helm.
When activated, the pressure switch will
automatically control the pump. As pressure
builds in the washdown hose, the pump will
shut off. When the washdown hose is in use
and the pressure drops, the pump will turn
on. Turn the switch off when the washdown
is not in use.
!
DANGER
FIRE OR EXPLOSION HAZARD
Fuel and their vapors are highly explo-
sive when exposed to open flame or
spark, resulting in death or serious
injury. Do not confuse deck fills.
NOTICE
DO NOT allow the fresh water pump to
run dry; damage to the pump can
occur. The fresh water pump works on
demand and WILL NOT shut off when
the tank is empty. Turn the water
pump switch "OFF" when the system
is not in use. Operating any pump
from a low-charged battery can lead to
a pump failure. Keep the batteries
properly charged. The fresh water
system must be properly winterized
prior to winter lay-up. Refer to Winter-
izing.
Summary of Contents for C238
Page 1: ...October 2015 December 2015...
Page 2: ...NOTICE This manual may contain pictures or discussions of options not available on SE models...
Page 6: ......
Page 10: ...Operator Notes 8 C238...
Page 20: ...Operator Notes 2 6 C238...
Page 34: ...5 6 Operator Notes C238...
Page 36: ...6 2 Operator Notes C238...
Page 42: ...8 2 Operator Notes C238...
Page 50: ...Operator Notes 9 8 C238...
Page 74: ...12 6 Operator Notes C238...
Page 80: ...Operator Notes A 6 C238...
Page 82: ...Appendix B Maintenance Log Date Hours Dealer Service Repairs B 2 C238 Maintenance Log...
Page 83: ...Maintenance Log B 3 Appendix B C238 Date Hours Dealer Service Repairs...
Page 84: ...Appendix B Maintenance Log Date Hours Dealer Service Repairs B 4 C238...
Page 85: ...Boating Accident Report C 1 Appendix C C238 Boating Accident Report...
Page 86: ...C 2 Appendix C Boating Accident Report C238...
Page 87: ...Float Plan D 1 Appendix D C238 Float Plan...
Page 88: ...Operator Notes D 2 C238...
Page 92: ...Operator Notes E 4 C238...
Page 93: ...Schematics F 1 Appendix F C238 Schematics...
Page 94: ...F 2 Appendix F Schematics C238...
Page 95: ...Schematics F 3 Appendix F C238...
Page 96: ...F 4 Appendix F Schematics C238...
Page 97: ...Schematics F 5 Appendix F C238...
Page 98: ...F 6 Appendix F Schematics C238...
Page 99: ...Schematics F 7 Appendix F C238...
Page 100: ...F 8 Appendix F Schematics C238...
Page 101: ...Schematics F 9 Appendix F C238...
Page 102: ...F 10 Appendix F Schematics C238...
Page 103: ...Schematics F 11 Appendix F C238...
Page 104: ...F 12 Appendix F Schematics C238...
Page 105: ...Schematics F 13 Appendix F C238...
Page 106: ...F 14 Appendix F Schematics C238...
Page 107: ...Schematics F 15 Appendix F C238...
Page 108: ...F 16 Appendix F Schematics C238...
Page 109: ...Schematics F 17 Appendix F C238...
Page 110: ...F 18 Appendix F Schematics C238...
Page 111: ...Schematics F 19 Appendix F C238...
Page 112: ...F 20 Appendix F Schematics C238...
Page 113: ...Schematics F 21 Appendix F C238...
Page 114: ...F 22 Appendix F Schematics C238...
Page 115: ...Schematics F 23 Appendix F C238...
Page 116: ...Operator Notes F 24 C238...
Page 117: ......
Page 118: ......