2. Disconnect the outlet hose from the pump and drain all
water from the air conditioning unit. If you are not
sure if all water has drained from the system, use
compressed air blown in from the air conditioning
water outlet, on the starboard hull side, to be sure.
Be very careful with compressed air. Too much
pressure or volume can damage the raw water
system.
3. Run the pump for a few seconds to be sure there is no
water left in it. Re-connect the hoses to the pump and
re-assemble the strainer.
When reconnecting raw water hoses, be certain to
tighten clamps well. Leaking fitting on raw water
hoses can sink the boat.
Air Conditioning Unit
Strainer
Condensate Drain
Raw Water Pump
Overboard Discharge
Raw Water Intake
Seacock
Cold Air Discharge
Figure 6-2: Air Conditioning Schematic