PARAMETER
DEFAULT
DESCRIPTION
P101
Transducer
1 = dB Mach3
Type of transducer being used
P706
Volume units
1 = Litres
Units of flow as on display and used for
calculations.
1 = Litres 2 = Cubic metres
3 = Cubic Feet 4 = UK gallons
5 = US gallons 6 = Mil. USG
P707
Time Units
1 = per second
Units of time that volume units will be
displayed and calculated in
P104
Measurement units
4 = feet
Used to enter dimensions and displayed
where appropriate:
1 = Metres 2 = Centimetres
3 = Millimetres 4 = Feet
5 = Inches
P105
Empty Level
7.956 feet
Distance from the end of the transducer
horn (dB Mach3) or face of the
transducer to the material at the
bottom of the measuring element
P703
Minimum head
0.00 feet
Distance from empty point (P105) to
zero flow.
P704
Max head
7.956 feet
Distance from zero flow to max flow. It
should be noted that any change to
P704 updates P106 Span and vice versa.
P824
Totaliser Allocation
1 = Point 1
Enables the Totaliser to a specific point
of flow measurement or a combination
of flow when both points set to
measure Flow. For full list of options see
P824
P815
Aux Mode
2 = Level
Enables the Auxiliary display line to
display additional information whilst in
RUN mode. For full list of options see
P815