![Pulsar UltraTWIN Instruction Manual Download Page 165](http://html1.mh-extra.com/html/pulsar/ultratwin/ultratwin_instruction-manual_1624516165.webp)
PULSAR MEASUREMENT
165
P*704 Maximum Head
Enter the
head
value that represents
maximum flow,
enter in
Measurement
Units
P*104
.
Note any change to the value of this parameter will be reflected in P*106
(Span) and vice versa.
P*705 Maximum Flow
When
P*702
=
2 Ratiometric
enter the
flow rate
value that occurs at
maximum head (P*704)
, enter in
volume units
(
P7*06
) per
time units
(
P707
).
When
P*702 = 1 Absolute
, and all relevant flow parameters have been
entered, the
maximum flow
that occurs
at maximum head P*704
will be
calculated, after the unit is returned to RUN mode, and displayed in this
parameter in
volume units
(
P*706
) per
time units
(
P*707
).
P*706 Volume Units
Select the Volume Units to be used to display and calculate the flow rate
from the options below:
OPTION
DESCRIPTION
1 = Litres (Default)
Flow units will be calculated and displayed in
Litres
2 = Cubic metres
Flow units will be calculated and displayed in
m
3
3 = Cubic feet
Flow units will be calculated and displayed in
Ft
3
4 = UK Gallons
Flow units will be calculated and displayed in
UK Galls
5 = US Gallons
Flow units will be calculated and displayed in
US Galls
6 = Mil. USG
Flow units will be calculated and displayed in
Millions
of US Galls