24
25
system maintenanCe
The VP keypad requires a minimal amount of maintenance. However,
as with any electronic or mechanical device that is used regularly, a
small amount of maintenance done periodically will extend the life of the
product.
Periodic Visual Inspection
The VP should be inspected monthly. When performing the visual
inspection, look for the following items:
•
Damage caused by contact with vehicles, vandalism, etc.
•
Damage caused by water, rain, salt spray, etc.
•
Breaks or cracks in the sealant where the keypad mounts to the
gooseneck stand or wall
Periodic Cleaning
The keypad should be cleaned at least twice a year. More frequent cleaning
may be required in harsh environments.
Cleaning the Housing and Touchpad
Inspect and clean the housing and touchpad at least once a year. To clean
the housing, spray the unit with a mild household cleaner then wipe it with
a soft cloth. Do not use harsh chemicals, abrasives, or petroleum-based
products as they can damage the finish on the device. Do not immerse the
device in water or use a pressure washer. A small, soft brush (a toothbrush
works well) can be used to clean between the keys on the touchpad.
Remove the VP from the housing to inspect and clean the inside of the
unit. When inspecting the inside of the housing and the VP, look for the
following items:
•
Dirt or dust that has collected on the inside of the housing and the
circuit board
•
Signs of water damage or corrosion caused by prolonged contact to
water
•
Insects or insect droppings
Wipe out the inside of the housing with a soft cloth to remove any debris
that has collected. Do not use cleaners of any kind, including water, to
clean inside the housing or on the circuit board. A small can of compressed
air can be used to remove insects and dust from the circuit board.
Cleaning the Magnetic Stripe Reader
The VP is shipped with a cleaning card for the magnetic stripe reader (if
installed). The cleaning card is a small plastic card with a special cleaning
surface on one side that has been saturated with a cleaning solution. To
clean the reader, swipe the cleaning card several times through the slot
in the reader. Once the card has been used, it should be disposed of.
Additional cards can be ordered from PTI Security Systems. It is advisable
to keep a supply of cards on hand.