22
23
Presence Required Check.
After checking the tamper, the VP will check
to see if the Presence in Req option has been selected. If it has been
selected, the VP will check the input to see if a presence has been detected.
If this option has been turned off or if a presence has been detected, the
keypad will continue with the next security check. If the VP does not detect
a required presence, it will display the following message and no further
access attempts will be allowed.
Sorry –
No Presence Det
Maximum Attempts Check
The maximum attempts check is designed to discourage someone from
attempting numbers at random to enter the site. If the Max #Attempts
feature is set to a value other than zero, the VP will check to see if the
user has tried a code more than the allowed times. If not, the VP will allow
the user to enter the access code. If the maximum number of unsuccessful
attempts has been exceeded, the VP will display the following message
and disable any further access attempts. The VP will not allow any further
attempts until it has had 60 seconds without any key being pressed. If a
key is pressed while this message is displayed, the 60 second timer starts
over.
Sorry….
* See Manager *
Trip Relay Offline Check.
After the customer has entered their code,
the VP checks to see if the Trip Relay NoCom option has been enabled.
If it has been enabled and the keypad is not in communication with the
controller, then the VP will display the following message and further
access attempts will be allowed.
Access Granted