5
2. General Information
FluorPen
is a portable, battery-powered fluorometer that enables quick and precise measurement of
chlorophyll fluorescence parameters in the laboratory, greenhouse, or in the field. It can be effectively
used for studying photosynthetic activity, stress detection, herbicide testing, or mutant screening.
Affordable price and straight-forward two-button operation makes the FluorPen a perfect tool for
teaching photosynthesis. Because of its rapid measurement capability and large internal memory, the
FluorPen is also an invaluable tool for large plant-screening programs.
PAR-FluorPen FP 100-MAX-LM
includes all features of the FluorPen FP 100-MAX, i.e., it measures
chlorophyll fluorescence parameters Ft, QY, NPQ, OJIP, and Light Curve (QY).
Besides that, the PAR-FluorPen incorporates an integrated
Light Meter
for direct digital readouts of
Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm, the span in which plants use
energy during photosynthesis. PAR is measured as Photosynthetic Photon Flux Density (PPFD), which is
indicated by units of quanta (photons) per unit time per unit surface area. The sensor has a uniform
response to photons withing the 400-700 nm waveband. Instant readouts are provided as average values
of 20 measurements.
Measured data are sequentially stored in the internal FluorPen or PAR-FluorPen memory. Data transfer to
a PC is via USB or Bluetooth communication. Comprehensive FluorPen 1.0 software provides data transfer
routines and many additional features for data presentation in tables and graphs.
FluorPen versions:
FluorPen FP 100-MAX
Includes one of the communication modules (Bluetooth, USB, or serial), FluorPen 1.0 software, protocol
update, user's guide. Measures Ft, QY, NPQ, OJIP, and Light Curve. Equipped with a standard leaf-clip.
FluorPen FP 100-MAX-D
Includes one of the communication modules (Bluetooth, USB, or serial), FluorPen 1.0 software, protocol
update, user's guide. Measures Ft, QY, NPQ, OJIP, and Light Curve. Adapted for use with detachable leaf-
clips; leaf clips sold separately.
FluorPen FP 100-MAX-W
This version of the FluorPen FP 100-MAX is equipped with a special open leaf-clip that enables
measurements in ambient light. The open leaf-clip may is supplied with a cover for short term dark
adaptation of measured samples.
FluorPen FP 100
Standard FluorPen version with no PC communication. Data are saved to the device internal memory only.
FluorPen FP 100-B
Standard FluorPen version supplemented with Bluetooth communication module and FluorPen 1.0
software for data transfer to a PC.
FluorPen FP100-U
Standard FluorPen version supplemented with USB communication module and FluorPen 1.0 software for
data transfer to a PC.
Summary of Contents for FluorPen FP 100
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...
Page 16: ...16...
Page 17: ...17...
Page 18: ...18...
Page 19: ...19...
Page 32: ...32...
Page 34: ...34 Example of OJIP protocol...
Page 36: ...36...
Page 37: ...37 Example of NPQ1 protocol Example of NPQ2 protocol...
Page 39: ...39...
Page 40: ...40...
Page 41: ...41 Example of LC1 protocol Example of LC2 protocol...
Page 42: ...42 Example of LC3 protocol...