Elastomer Options
A2 Metal Pumps
Material
Diaphragm
P/N
Valve Ball
P/N
Valve Seat O-Ring
P/N
Valve Seat
P/N
Polyurethane
02-1010-50
02-1080-50
02-1200-50
N/A
BUNA-N
02-1010-52
02-1080-52
02-1200-52
N/A
Neoprene
02-1010-51
02-1080-51
N/A
N/A
EPDM
02-1010-54
02-1080-54
02-1200-54
N/A
FKM
®
02-1010-53
02-1080-53
N/A
N/A
Wil-
Flex™
02-1010-58
02-1080-58
02-1200-58
N/A
Saniflex™
02-1010-56
02-1080-56
02-1200-56
N/A
PTFE
02-1010-55
02-1080-55
02-1200-55
N/A
Stainless Steel
N/A
N/A
N/A
02-1120-03
Aluminum
N/A
N/A
N/A
02-1120-01
Alloy C
N/A
N/A
N/A
02-1120-04
Electrical Information
NEMA 4
1
/ UL / CSA
Part Number
Voltage ±10%
Power (W)
±10%
Current (A)
Resistivity
( )
DC
AC
DC
AC
60 Hz
50 Hz
Inrush
Holding
00-2110-99-150
24
48
44
4.8
.20
.20
.20
121
00-2110-99-151
12
24
22
4.8
.40
.40
.40
32
00-2110-99-155
60
120
110
4.8
.08
.08
.06
840
NEMA 7 / UL / CSA
Part Number
Voltage ±10%
Power (W)
±10%
Current (A)
Resistivity
( )
DC
AC
DC
AC
60 Hz
50 Hz
Inrush
Holding
00-2110-99-153
12
24
22
7
.60
.55
.32
19
00-2110-99-154
24
48
44
7
.30
.30
.18
75
00-2110-99-156
60
120
110
7
.12
.13
.06
475
INTERNATIONAL EXPLOSION PROOF / CENELEC / PTB FILE # EX-91.C.2027
Part Number
DC Voltage ±10%
Power (W)
±10%
Current (A)
Resistivity
( )
Inrush
Holding
00-2110-99-157
24
3.3
.135
.135
177
1
NEMA 4 and IEC 144/855420 I.P. 66 for dust-tight, watertight corrosion resistant.
Section 9