PERFORMANCE
A2P METAL
RUBBER-FITTED
Height ............................ 279 mm (11.0")
Width ............................. 267 mm (10.5")
Depth ............................... 229 mm (9.0")
Est. Ship Weight ... Aluminum 12 kg (26 lb)
Stainless Steel 16 kg (36 lb)
Alloy C 18 kg (40 lb)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet .................................... 19 mm (3/4")
Suction Lift ..................7.43 m Dry (24.4')
9.68 m Wet (31.8')
Disp. Per Stroke
1
............ 0.35 L (0.092 gal)
Max. Flow Rate ............ 129 lpm (34 gpm)
Max. Size Solids ................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 37.9 lpm (10 gpm)
against a discharge pressure head of
3.6 bar (52 psig) requires 4.1 bar (60 psig)
and 23.8 Nm
3
/h (14 scfm) air consumption.
(See dot on chart.).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters
will fall in the center of the pump’s performance curve.
A2P METAL
PTFE-FITTED
Height ............................ 279 mm (11.0")
Width ............................. 267 mm (10.5")
Depth ............................... 229 mm (9.0")
Est. Ship Weight ... Aluminum 12 kg (26 lb)
Stainless Steel 16 kg (36 lb)
Alloy C 18 kg (40 lb)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet .................................... 19 mm (3/4")
Suction Lift ................. 6.55 m Dry (21.5')
8.99 m Wet (29.5')
Disp. Per Stroke
1
............ 0.20 L (0.054 gal)
Max. Flow Rate ............ 121 lpm (32 gpm)
Max. Size Solids ................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 37.9 lpm (10 gpm)
against a discharge pressure head of 3.4
bar (49 psig) requires 4.1 bar (60 psig) and
35.7 Nm3/h (21 scfm) air consumption.
(See dot on chart.).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters
will fall in the center of the pump’s performance curve.