![PSG Dover WILDEN Accu-Flo A2 Engineering, Operation & Maintenance Download Page 10](http://html1.mh-extra.com/html/psg-dover/wilden-accu-flo-a2/wilden-accu-flo-a2_engineering-operation-and-maintenance_1622715010.webp)
WIL-10060-E-03
Wilden
®
10
PERFORMANCE
A2T METAL
RUBBER-FITTED
Height ............................ 279 mm (11.0")
Width ............................. 267 mm (10.5")
Depth ............................... 191 mm (7.5")
Est. Ship Weight ... Aluminum 12 kg (26 lb)
Stainless Steel 16 kg (36 lb)
Alloy C 18 kg (40 lb)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet .................................... 19 mm (3/4")
Suction Lift ..................7.25 m Dry (23.8')
8.66 m Wet (28.4')
Disp. Per Stroke
1
............ 0.33 L (0.087 gal)
Max. Flow Rate ............ 102 lpm (27 gpm)
Max. Size Solids ................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 37.9 lpm (10 gpm)
against a discharge head pressure of
2.7 bar (39 psig) requires 4.1 bar (60 psig)
and 17.9 Nm
3
/h (10.5 scfm) air
consumption. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters
will fall in the center of the pump’s performance curve.
A2T METAL
PTFE-FITTED
Height ............................ 279 mm (11.0")
Width ............................. 267 mm (10.5")
Depth ............................... 191 mm (7.5")
Est. Ship Weight ... Aluminum 12 kg (26 lb)
Stainless Steel 16 kg (36 lb)
Alloy C 18 kg (40 lb)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet .................................... 19 mm (3/4")
Suction Lift ..................4.85 m Dry (15.9')
8.66 m Wet (28.4')
Disp. Per Stroke
1
............ 0.15 L (0.039 gal)
Max. Flow Rate .............. 68 lpm (18 gpm)
Max. Size Solids ................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 37.9 lpm (10 gpm)
against a discharge pressure head of
1.03 bar (15 psig) requires 4.1 bar
(60 psig) and 21.3 Nm
3
/h (12.5 scfm) air
consumption. (See dot on chart.).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Section 5
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters