5.4 Physical Drive
Choose this option from the Main Menu to select a disk drive and to perform the
functions listed below.
5.4.1 Create Pass-Through Disk
A Pass-Through Disk is a disk drive not controlled by the internal RAID subsystem
firmware and thus cannot be a part of a Volume Set. A Pass-Through disk is a
separate and individual Raid Set. The disk is available to the host as an individual
disk. It is typically used on a system where the operating system is on a disk not
controlled by the RAID firmware.
To create pass-through disk, click on the
Create Pass-Through
link under the
Physical Drives main menu. The setting function screen appears.
Select the disk drive to be made as Pass-Through Disk and configure the Pass-
Through Disk attributes, such as the Cache Mode, Tagged Command Queuing, and
Fibre Channel/LUN Base/LUN for this volume.