![Proware EP-2243D-F4S3 User Manual Download Page 120](http://html.mh-extra.com/html/proware/ep-2243d-f4s3/ep-2243d-f4s3_user-manual_1620842120.webp)
Fibre to SAS/SATA II RAID Subsystem
120
User Manual
Appendix 2 Redundant Controllers Switch Function
NOTE: There are 2 options to test/simulate controller failure:
1.
A switch (connected to thumbscrew) is included in the
Controller. When testing/simulating RAID Controller failure in
dual controller mode, the thumbscrew can be loosened, and the
switch will be automatically triggered and put the Controller in
“Faulty” state (FLT LED will be blinking red). Refer to Section 3.
2.
Use the command “HaltCtrl0” in web GUI. Refer to Section 2.
1. The Location of the Switch in the Controller
The Controller
Rear Part
Front Part
(Backplane
Connector
Side)
(Controller
Panel
Side)
2. Using Command in Web GUI to Simulate Controller Failure
1.
Prepare network environment to have connection to proRAID Manager Web GUI
of Controller 1 or Controller 2.
2.
To test Controller 1 Failure, login to Controller 1 Web GUI.
NOTE: If needed to test Controller 2 Failure, login to Controller 2
Web GUI.
3.
Under RAID Set Functions menu, select “Rescue Raid Set”.
Summary of Contents for EP-2243D-F4S3
Page 1: ...Fibre to SAS SATA II RAID Subsystem User Manual Revision 1 2 ...
Page 44: ...Fibre to SAS SATA II RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA II RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA II RAID Subsystem 46 User Manual ...
Page 47: ...Fibre to SAS SATA II RAID Subsystem User Manual 47 ...
Page 48: ...Fibre to SAS SATA II RAID Subsystem 48 User Manual ...
Page 56: ...Fibre to SAS SATA II RAID Subsystem 56 User Manual ...