Fibre to SAS/SATA II RAID Subsystem
116
User Manual
Case 2: One Volume Set Mapped to Channel 0&1 LUN 0
When one Volume Set is created and mapped to
Channel 0&1
LUN 0
,
the Volume Set is
Active in Controller 1
Ports 0 and 1
(Host A and Host
B channels), and
Standby in Controller 2
.
In this case, Ports 0 and 1 in Controller 1 will be both active and use
Load
Balance
mode.
Volume Channel/LUN
Mapping
Remarks
Volume Set #000
0&1 / 0
Channel 0&1 => Ports
0
and
1
/
LUN 0 => Controller
1
IMPORTANT: MPIO must be configured on the host system(s), in
order for redundant LUNs (two paths via Controller 1 and 2) to
appear as single LUNs.
Case 3: Two Volume Sets each Mapped to Channel 0
When a Volume Set is created and mapped to
Channel 0
LUN 0
, the
Volume Set is
Active in Controller 1
Port 0
(Host A channel), and
Standby in Controller 2
.
When a second Volume Set is created and mapped to
Channel 0
LUN 1
,
the Volume Set is
Active in Controller 2
Port 0
(Host A channel), and
Standby in Controller 1
.
Volume Channel/LUN
Mapping Remarks
Volume Set #000
0 / 0
Channel 0 => Port 0 /
LUN 0 => Controller
1
Volume Set #001
0 / 1
Channel 0 => Port 0 /
LUN 1 => Controller
2
NOTE: All even number LUNs assigned to Volume Sets will be Active in
Controller 1 and all odd number LUNs assigned to Volume Sets
will be Active in Controller 2.
IMPORTANT: MPIO must be configured on the host system(s), in
order for redundant LUNs (two paths via Controller 1 and 2) to
appear as single LUNs.
Summary of Contents for EP-2243D-F4S3
Page 1: ...Fibre to SAS SATA II RAID Subsystem User Manual Revision 1 2 ...
Page 44: ...Fibre to SAS SATA II RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA II RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA II RAID Subsystem 46 User Manual ...
Page 47: ...Fibre to SAS SATA II RAID Subsystem User Manual 47 ...
Page 48: ...Fibre to SAS SATA II RAID Subsystem 48 User Manual ...
Page 56: ...Fibre to SAS SATA II RAID Subsystem 56 User Manual ...