![Proware EP-2243D-F4S3 User Manual Download Page 131](http://html.mh-extra.com/html/proware/ep-2243d-f4s3/ep-2243d-f4s3_user-manual_1620842131.webp)
Fibre to SAS/SATA II RAID Subsystem
User Manual
131
2.
When Disk Fails, How to Use Disk Power Function Command in Web GUI;
With Hot Spare Configured
NOTE: When a disk fails and the Volume Set use RAID Level with
redundancy, such as RAID Level 5, the Volume Set state will
become Degraded. If there is a Hot Spare configured, the Hot
Spare will automatically rebuild the Raid Set / Volume Set.
1.
Check which Disk has failed. In this example,
Disk
in
Enclosure#1 Slot#1
has
failed. The disk failure event can also be verified in the System Event Information
(event log) when you use “View Events/Mute Beeper” under System Controls. In
this example,
Disk
in
Enclosure#1 Slot#2
is configured as
Hot Spare
.
NOTE: The Disk used in this example is from Enclosure#1 Slot#1.
Make sure to verify which
Enclosure#
and
Slot#
the failed disk is
located.
2.
The Volume Set will be rebuilt automatically using the Hot Spare (Disk in Slot#2).
The System Event Information will show the “Rebuilding” event.
Summary of Contents for EP-2243D-F4S3
Page 1: ...Fibre to SAS SATA II RAID Subsystem User Manual Revision 1 2 ...
Page 44: ...Fibre to SAS SATA II RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA II RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA II RAID Subsystem 46 User Manual ...
Page 47: ...Fibre to SAS SATA II RAID Subsystem User Manual 47 ...
Page 48: ...Fibre to SAS SATA II RAID Subsystem 48 User Manual ...
Page 56: ...Fibre to SAS SATA II RAID Subsystem 56 User Manual ...