The Hardware Monitor Information provides the temperature and voltage levels of the RAID
subsystem. All items are also unchangeable. When the threshold values are exceeded, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
Controller Board Temperature
> 60 Celsius
HDD Temperature
> 60 Celsius
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V