HYPER3™ IN-LINE REGULATOR
ADJUSTMENTS AND MAINTENANCE
HYPER3™ REGULATOR DIS-ASSEMBLY INSTRUCTIONS
Before performing maintenance on the Hyper3™ regulator, ensure that the RAIL™ is completely
degassed and then unscrew the Hyper3™ from the RAIL™ marker.
To disassemble the Hyper3™ regulator you will need a C-clip tool or a strong pick. Remove the C-
clip from the bottom of the Hyper 3 reg. Next, unscrew the Brass seat housing from the body
with a 3⁄16” Allen key.
To change the seat, pull out the old seat from the housing with a sharp object. Insert the new seat
in place and push it down with a flat object. Notice that it takes about 2000 shots for the seat to
perfectly sit into the seat housing. This is called the break in period for the regulator. Remember
to apply lube to the 010 on the brass reg seat housing before re-assembly. Further disassembly to
service the top section of the Hyper3™ should be performed by a trained Tech.
C-CLIP
SEAT HOUSING
BODY
011 BN070
REGULATOR SEAT