ProTec Polymer Processing GmbH
Foerdergeraet_FG201-FG206_BA_1v0_2018_en
66
16.
Adjust the pin (10).
The extended piston must close the flap.
17.
Supply the control valve with compressed air.
18.
Press the manual override (14) on the control valve.
19.
The piston extends.
20.
Hold the piston (9) and screw out the pin (10).
21.
Until it presses the flap tightly on the metal edge of the nozzle.
22.
Lock the pin (10) with the nut (11).
23.
Interrupt the compressed air supply.
8.5.2 Replacing compressed air cylinder 1
1.
Pull off the compressed air hose (13) from the compressed air nipple (5) and loosen the
nut (6).
2.
Screw out the compressed air cylinder (57b).
3.
Hold the piston (9) of the compressed air cylinder tight.
4.
Screw off the pin (10) and the nut (11).
5.
Tightly screw nuts (6, 11) and the pin (10) onto a new compressed air cylinder:
Screw on the nut (11) up to the end of the threads.
Apply Loctite 272 on the pin threads (10).
6.
Screw on the pin up to the nut (11): Screw in the compressed air cylinder (57): The
flange on the inside of the container must end flush with the sleeve.
7.
The nipple (5) must point upwards.
8.
Tighten the nut (6).
9.
Stick the compressed air hose (13) in the nipple (5).
10.
Adjust the pin (10).
The extended piston must close the flap.
11.
Supply the control valve with compressed air.