8.2
Service
8.3
Removing the blower attachment
The blower is equipped with a commutation motor. The carbon brushes of this motor are subject
to runtime-dependent wear. Therefore they must be replaced regularly.
CAUTION!
Heat development due to worn carbon brushes.
If Fault 311 occurs, the device must be shut off. The carbon
brushes must be replaced, since otherwise high heat
development and damage to the blower will occur.
Information
If the carbon brushes are replaced once and the blower shuts
off again, then it must be replaced.
8.3.1 Before maintenance
Warning!
Risk of burns due to hot surfaces.
Before performing maintenance work let the device cool
off.
1.
Stop the conveying cycle and disconnect the device from power.
2.
Remove the blower attachment (21).
3.
Unscrew the screws (3) on the lower edge of the hood and remove the hood.
4.
Loosen the plug connections and remove the compressed air coupling.