Chapter 2: Getting Started
11
Correct SCSI termination procedures require that the first and last devices on the
SCSI bus be terminated. If the first or last device is not terminated, or if devices
other than the first and last are terminated, erratic SCSI bus performance may
occur.
Typically, the system or host adapter is the first device and is already terminated.
When installing the UltraTrak disk array on a SCSI bus with other devices, make
sure the above rules are observed with all devices on the SCSI bus. Consult your
system and/or host adapter manual for additional information on correct
termination procedure.
SCSI-IN
SCSI-OUT/TERM
Figure 7. SCSI Terminator attaches to the SCSI Output Connector.
Caution
Improper system operation may occur if the SCSI termination is
incorrect. Proper termination and SCSI-3 compliant cables must be used.
A SCSI-3 compliant cable is included with the UltraTrak.
Terminator
SCSI Output
Connector