Configuring the A-module (DXMaA) (actuator module)
When you change or start up the DXMaA module,
press <DXMaA Reload> to
synchronise the data.
A-module (DXMaA)
OFF
System overview
2021-06-22
14:21:28
START 1
Information
Frequency outputs 1 - 3
Digital inputs 1 - 3
Diagnostics
mA outputs 1- 3
A3194
Send e-mail enquiry
Node-ID
Serial number
Software version
Identity code
A-Module (DXMaA)
Reload
13
2006136135
3016
DXMAAW2000
Fig. 9: Configuring the A-module (DXMaA) (actuator module)
6.1 Frequency outputs 1 ... 3
You can set 3 frequency outputs separately from each other with
the corresponding function. You can limit the maximum frequency
(strokes/minute) of the set pump.
R1
Relay, function
Not assigned
Pump for pH raising agent
Pump for pH lowering agent
maximum frequency
0 ... 500 strokes/minute
R2
Relay, function
Not assigned
Pump for ORP raising agent
Pump for chlorine raising agent
Pump for pH lowering agent
maximum frequency
0 ... 500 strokes/minute
R3
Relay, function
Not assigned
Pump for ORP raising agent
Pump for chlorine raising agent
Pump for flocculant
Maximum frequency
0 ... 500 strokes/minute
6.2 Digital inputs 1 ... 3
You can then define 3 digital input signals if a pump function is
defined in the frequency outputs. You can also define the con‐
nector type NC or NO.
Configuring the A-module (DXMaA) (actuator module)
19