4
Commissioning the DXMaX module on the DULCOMARIN
®
3
4.1 Entering the number of swimming pools
To start up a multiple pool system, first increase the number of
swimming pools on the DULCOMARIN
®
3. Use the system settings
to enter the number of swimming pools.
Note the following if the original DULCOMARIN
®
II was not
assigned to its own swimming pool:
n
To rule out a conflict with the IO module board fitted, increase
the number of swimming pools in the DULCOMARIN
®
3 by 1.
n
This swimming pool is not used and only serves to assign the
IO module board fitted to this swimming pool. Following a
power failure, for example, the IO module board fitted will be
automatically assigned to this swimming pool.
Unit settings
System settings
Selected number of pools
Number of pools
A3189
3 pools
2 pools
1 pool
Fig. 3: Entering the number of swimming pools
4.2 Manual assignment of the CAN modules
Connect the CAN modules one after the other to the CAN bus. To
do so, repeat the following chapters 4.2 and 4.3 for each further
CAN module.
1.
Select a swimming pool using the number of the swimming
pool under System settings ➨
‘Networking’ .
An overview of the assigned units already available in the
pool then appears.
BUS details – pool
A3191
Change
Fig. 4: Overview of the modules already available in the selected
pool.
Commissioning the DXMaX module on the DULCOMARIN
®
3
12
Summary of Contents for DULCOMARIN 3 Compact
Page 27: ...27 ...