15.2  Routing diagram, manual deactivation of the latch function 
 

 

 

 

 

Summary of Contents for UMU 100-A-B

Page 1: ...Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com User manual UMU 100 A B from page 01 UMU 100 B B from page 34 User manual Univer...

Page 2: ...10 5 Decomposition of the system UMU 100 A B 11 6 Universal measuring transducer UMU 100 A B 12 7 Applications 13 8 Front display programming front UMU FD 14 9 Mounting demounting the UMU FD 15 10 Ele...

Page 3: ...ds 43 4 Commissioning and operation 44 4 1 Before mounting 44 4 2 Mouning Installation configuration 44 5 How to demount the UMU 100 B B 45 6 Universal transducer UMU 100 B B 46 7 Applications 47 8 Fr...

Page 4: ...deactivation of the latch function 69 16 Help text overview 70 17 Grapic depiction 72 17 1 Grapic depiction of latch function setpoint 72 17 2 Graphic depiction of latch function window 73 17 3 Graphi...

Page 5: ...the serial number on the type label is no longer readable e g due to mechnical damage tracebility is no longer ensured The sensors described in the user manual are developed and manufactured according...

Page 6: ...n the following Prior to the commissioning of the device this manual must be examined carefully Only qualified personnel technicans should install this device If the equipment is used in manner not sp...

Page 7: ...isulation symbol is the symbol that the device meets special requirements for insulation 2 transport packaging and storage 2 1 transport Inspect the device for a damage that may have occurred during t...

Page 8: ...ors are persons who set or operate the pushbuttons or potentiometers of the product during normal operation and who have been familiarized with the contents of this manual Receipt and unpacking Unpack...

Page 9: ...ications observe the applicable standards and directives e g for hazardous media such as Acetylene flammable or toxic substances as well as refrigeration plants and compres sors If the relevant regula...

Page 10: ...n the units can be mounted side by side without an air gap between them even at an ambient temperature of 60 C Configuration monitoring 2 point process calibration and more are performed with either t...

Page 11: ...rail by loosening the lower catch When the front LED is red display shows AO ER The device has been developed with a high level of safety Therefore a continuous measurement of the output current take...

Page 12: ...or linear movements with connected potentiometers Power supply and signal isolator for 2 wire measuring transducer Process control with standard analog output Galvanic isolation of analog signals and...

Page 13: ...c GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 7 Applications Input signals Output sig...

Page 14: ...ating the function key Application Communications interface for modification of operational parameters in UMU 100 Can be moved from one UMU 100 device to another and download the configuration of the...

Page 15: ...l office promesstec com I Internet www promesstec com 9 Mounting demounting the UMU FD 1 Insert the tabs of the UMU FD into the holes at the top of the UMU 100 2 Hinge the UMU FD down until it snap in...

Page 16: ...23 5 x 104 mm Dimensions HxWxD with UMU FD 109 x 23 5 x 116 131 mm Weight approx 155 g Weight with UMU FD approx 170 g 185 g DIN rail type DIN EN 60715 35 mm Cable cross section 0 13 2 08 mm2 AWG 26...

Page 17: ...sistance 0 1 0 01 C Potentiometer 0 1 0 01 C TC type E J K L N T U 1 C 0 05 C C TC type R S W3 W5 LR 2 C 0 2 C C TC type B 85 200 C 4 C 0 4 C C TC type B 200 1820 C 2 C 0 2 C C EMC immunity influence...

Page 18: ...50 C 1760 C IEC 60584 1 S 50 C 1760 C IEC 60584 1 T 200 C 400 C IEC 60584 1 U 200 C 600 C DIN 43710 W3 0 C 2300 C ASTM E988 90 W5 0 C 2300 C ASTM E988 90 LR 200 C 800 C GOST 3044 84 Cold junction comp...

Page 19: ...anges 0 20 4 20 20 0 and 20 4 mA Load max 800 Load stability 0 01 of span 100 Sensor error detection 0 3 5 23 mA none NAMUR NE 43 Up Downscale 23 mA 3 5 mA Output limitation 4 20 and 20 4 mA signals 3...

Page 20: ...V 0 10 V 2 10 V IN LO 25 mV IN HI 12 V CURR 0 20 mA 4 20 mA IN LO 1 05 mA IN HI 25 05 mA LIN R 0 800 IN LO 0 IN HI 1075 0 10 k IN LO 0 IN HI 110 k POTM IN LO 0 5 IN HI 100 5 TEMP TC RTD IN LO tempera...

Page 21: ...alog output current AO ER 1 No load on the current output only S4 20 S20 4 mA Communications test UMU 100 UMU FD NO CO Connection error Check that input signal matches input configuration IN ER 1 Erro...

Page 22: ...chsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 12 Connections Supply Inputs Ausg nge Bitte die CJC Ansc...

Page 23: ...23 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 13 Block diagram...

Page 24: ...ult state 1 0 wit hout saving the changed values or parameters 14 2 Further explanations Password protection Programming access can be blocked by assigning a password The password is saved in the devi...

Page 25: ...this menu point or choose another type of input signal the device will return to factory calibration Process simulation function SIM In the menu point EN SIM it is possible to si mulate an input ignal...

Page 26: ...29 29 E Mail office promesstec com I Internet www promesstec com always displayed in C and F This is selected in the menu point after selection of temperature input CJC In the CJC menu you can choose...

Page 27: ...t www promesstec com 15 routing diagram If no key is activated for 1 minute the display will return to the default state 1 0 wit hout saving configuration changes Increase value choose next parameter...

Page 28: ...28 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 29: ...29 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 30: ...c GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 15 1 Flussdiagramm erweiterte Einstellu...

Page 31: ...type Select TC L as sensor type Select TC N as sensor type Select TC R as sensor type Select TC S as sensor type Select TC T as sensor type Select TC U as sensor type Select TC W3 as sensor type Sele...

Page 32: ...ginal packaging or similar As protection against damage can be used for example antistatic film insulating material labeling as a sensetive measuring device 17 3 Liability To the extent the instructio...

Page 33: ...ow are able to follow these should connect the device Should there be any doubt as to the correct handling of the device please contact your local distributor However you can also contact promesstec G...

Page 34: ...5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 19 order code order code UMU 100 order example UMU 100 A B Limit relay A without limit relay B with...

Page 35: ...Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com User manual Universal measuring transducer UMU 1...

Page 36: ...10 5 Decomposition of the system UMU 100 A B 11 6 Universal measuring transducer UMU 100 A B 12 7 Applications 13 8 Front display programming front UMU FD 14 9 Mounting demounting the UMU FD 15 10 Ele...

Page 37: ...ds 43 4 Commissioning and operation 44 4 1 Before mounting 44 4 2 Mouning Installation configuration 44 5 How to demount the UMU 100 B B 45 6 Universal transducer UMU 100 B B 46 7 Applications 47 8 Fr...

Page 38: ...deactivation of the latch function 69 16 Help text overview 70 17 Grapic depiction 72 17 1 Grapic depiction of latch function setpoint 72 17 2 Graphic depiction of latch function window 73 17 3 Graph...

Page 39: ...ust be observed If the serial number on the type plate is no longer legible e g due to mechanical damage traceability is no longer ensured The sensors described in the operating manual are developed a...

Page 40: ...ssioning of the device this installation guide must be examined carefully Only qualified personnel technicians should install this device If the equipment is used in a manner not specified by the manu...

Page 41: ...tion symbol shows that the device is protected by double or reinforced insulation 2 Transport packaging and storage 2 1 Transport Inspect the device for any damage that may have occurred during transp...

Page 42: ...accordance with safety regulations Operators being familiar with the contents of this manual adjust and operate the knobs or potentiometers during normal operation Receipt and unpackaging Unpack the d...

Page 43: ...ards and directives for special applications e g for hazardous media such as acetylene flammable or toxic substances and for refrigeration systems and compressors Failure to observe the relevant regul...

Page 44: ...stallation configuration Very low power consumption means units can be mounted side by side without an air gap even at 60 C ambient temperature Configuration monitoring 2 point prozess calibration and...

Page 45: ...AO ER The UMU 100 has been developed with a high safety level Therefore a continuous measurement of the outgoing current is carried out on a 4 20mA output signal If the current output signal is differ...

Page 46: ...ed potentiometer Power supply and signal isolator for 2 wire transmitters Process control with 2 pairs of potential free relay contacts and analog output Galvanic separation of analog signals and meas...

Page 47: ...c GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 7 Applications Input signals Output sig...

Page 48: ...the function key Application Communications Interface for modification of operational parameters UMU 100 Can be moved from one UMU 100 device to another and download the configuration of the first un...

Page 49: ...com I Internet www promesstec com 9 Mounting demounting the UMU FD 1 Inserting the two fixing pins of the UMU FD into the openings on the upper front panel of the UMU 100 2 Snap the UMU FD display in...

Page 50: ...109 x 23 5 x 104 mm Dimensions HxBxT with UMU FD 109 x 23 5 x 116 131 mm Weight approx 175 g Weight with UMU FD approx 190 g 205 g DIN rail type DIN EN 60715 35 mm Cable cross section 0 13 2 08 mm2 A...

Page 51: ...S W3 W5 LR 2 C 0 2 C C TC type B 85 200 C 4 C 0 4 C C TC type B 200 1820 C 2 C 0 2 C C EMC Immunity Influence 0 5 pf span Extended EMC Immunity NAMUR E 21 A criterion burst 1 of span Input specificat...

Page 52: ...584 1 IEC 60584 1 IEC 60584 1 IEC 60584 1 DIN 43710 ASTM E988 90 ASTM E988 90 GOST 3044 84 Cold Junction compensation CJC via external sensor in connector CJC 20 28 C 1 C 20 20 C 28 70 C 2 C via inter...

Page 53: ...Output limitation 4 20 and 20 4 mA signals 3 8 20 5 mA 0 20 and 20 0 mA signals 0 20 5 mA Current limit 28 mA Voltage output Signal range 0 10 VDC Programmable signal ranges 0 1 0 2 1 0 10 0 5 1 5 2 1...

Page 54: ...54 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 55: ...1 V IN LO 25 mV IN HI 1 2 V 0 10 V 2 10 V IN LO 25 mV IN HI 12 V CURR 0 20 mA 4 20 mA IN LO 1 05mA IN HI 25 05 mA LIN R 0 800 IN LO 0 IN HI 1075 0 10 k IN LO 0 IN HI 110 k POTM IN LO 0 5 IN HI 100 5...

Page 56: ...of analog output current AO ER 1 No load on the current output only S4 20 S20 4 mA Communications test UMU FD UMU 100 NO CO Connection error Check that Input signal matches Input configuration IN ER 1...

Page 57: ...omesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 12 Connections Supply Inputs Out...

Page 58: ...58 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 13 Block diagram...

Page 59: ...to the previous neu or return to the default state 1 0 without saving the changed values or parameters If no key is activated for 1 minute the display will return to the default state 1 0 without savi...

Page 60: ...ceeded and that the relay is in delay mode When the delay time has passed and the relay makes breakes the relay sign either displays or disappears 14 4 Signal and Sensor error indication without displ...

Page 61: ...d R2 cont The setpoint function is selected by choosing setpoint in the menu and entering the desired limit The device then works as a single limit switch An activated relay means that the contact is...

Page 62: ...bration the device will work according to this new adjustment If you later reject this menu point or choose another type of input signal the device will return to factory calibration Process simulatio...

Page 63: ...the Input signal type you can choose which process units should be displayed in text line 2 see table By selection of temperature Input the process va lue is always displayed in C or F This is selecte...

Page 64: ...64 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 65: ...65 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 15 routing diagram...

Page 66: ...66 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 67: ...67 promesstec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com...

Page 68: ...tec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 15 1 Routing diagram advanced setting...

Page 69: ...I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 15 2 Routing diagram manual deactivation of t...

Page 70: ...C W5 as sensor type Select TC Lr as sensor type 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 37 38 39 41 42 43 Select OFF function relay is permanently off Select POWER function relay indicates...

Page 71: ...brate Input high to process value Enable simulation mode Set the input simulation value Relay simulation use and to toggle relay 1 and 2 Enable password protection Set new password Enable Fastset func...

Page 72: ...Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 17 Grapic depiction 17 1 Grapic depiction of lat...

Page 73: ...tec GmbH I Niedersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 17 2 Graphic depiction of latch funct...

Page 74: ...ra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 17 3 Graphic depiction of rely action setpoint 17 4 Graphische...

Page 75: ...of dangerously hot pressure media escaping 18 2 Return For return of the device use the original packaging or similar As protection against damage can be used for example antistatic film isulating mat...

Page 76: ...9 Installation Only technicas who are familiar with the technical terms warnings and instructions in the manual and how are able to follow these should connect the device Should there be any doubt as...

Page 77: ...5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com 20 order code order code UMU 100 order example UMU 100 B B limit value A without limit value B with...